Publication:
The Relationship of Tear Osmolarity With Tear Meniscus Curvature and Contact Angles in Healthy Subjects: Anterior Segment Optical Coherence Tomography Study

dc.authorscopusid25633265700
dc.authorscopusid57192211319
dc.authorscopusid57279694800
dc.authorscopusid55125592200
dc.authorscopusid6603543240
dc.authorwosidKoçak, Nurullah/Aai-9905-2021
dc.contributor.authorYeter, Volkan
dc.contributor.authorKocak, Nurullah
dc.contributor.authorKalyoncu, Merve
dc.contributor.authorCan, Ertugrul
dc.contributor.authorAriturk, Nursen
dc.contributor.authorIDKocak, Nurullah/0000-0001-8811-7294
dc.contributor.authorIDYeter, Volkan/0000-0002-0357-9009
dc.date.accessioned2025-12-11T01:23:42Z
dc.date.issued2022
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Yeter, Volkan; Kocak, Nurullah; Kalyoncu, Merve; Can, Ertugrul; Ariturk, Nursen] Ondokuz Mayis Univ, Dept Ophthalmol, TR-55139 Samsun, Turkeyen_US
dc.descriptionKocak, Nurullah/0000-0001-8811-7294; Yeter, Volkan/0000-0002-0357-9009en_US
dc.description.abstractPurpose To evaluate the relationship of tear osmolarity (TO) with tear meniscus curvature and contact angles by anterior segment optical coherence tomography (AS-OCT) in healthy subjects. Methods The right eyes of 64 consecutive healthy subjects were included in the study. The eyes were scanned by AS-OCT for the measurements of upper and lower tear menisci. The geometrical components of the upper and lower menisci, including height, depth, area, and radius of the menisci, cornea-meniscus angle (alpha-angle), meniscus-eyelid angle (beta-angle), and curvature angle (theta-angle) were measured. TO was obtained by TearLab. All participants were administered Ocular Surface Disease Index questionnaires (OSDI), and tear film break-up time (TBUT), Schirmer I and II test measurements were also performed. Results There was no association of TO with height, depth, and area of both menisci while TO was negatively correlated to theta-angle and radius of the lower eyelid meniscus (r = - 0.41, P < 0.001 and r = - 0.40, P < 0.01, respectively). The theta-angle and the radius of the lower meniscus were also significantly associated with OSDI score, TBUT, Schirmer I and II (P < 0.01 for all). There was a statistically strong correlation between the theta-angle and the radius of the lower meniscus (r = 0.91, P < 0.001). Conclusion The curvature angle and radius of the lower meniscus are significantly associated with TO. The curvature angle of the lower meniscus is a useful non-contact measure that may provide information indirectly about the osmolarity and the quality of the tear.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1007/s10792-021-02022-6
dc.identifier.endpage268en_US
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue1en_US
dc.identifier.pmid34586570
dc.identifier.scopus2-s2.0-85116034983
dc.identifier.scopusqualityQ2
dc.identifier.startpage261en_US
dc.identifier.urihttps://doi.org/10.1007/s10792-021-02022-6
dc.identifier.urihttps://hdl.handle.net/20.500.12712/43402
dc.identifier.volume42en_US
dc.identifier.wosWOS:000701330600001
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectTear Osmolarityen_US
dc.subjectTear Meniscusen_US
dc.subjectGeometryen_US
dc.subjectAnglesen_US
dc.titleThe Relationship of Tear Osmolarity With Tear Meniscus Curvature and Contact Angles in Healthy Subjects: Anterior Segment Optical Coherence Tomography Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files