Publication:
The Effect of Pupil Dilation on Al-Scan Biometric Parameters

dc.authorscopusid55125592200
dc.authorscopusid56393872100
dc.authorscopusid56702793300
dc.authorscopusid6603543240
dc.contributor.authorCan, E.
dc.contributor.authorDuran, M.
dc.contributor.authorCetinkaya, T.
dc.contributor.authorAritürk, N.
dc.date.accessioned2020-06-21T13:33:47Z
dc.date.available2020-06-21T13:33:47Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Can] Ertugrul, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Duran] Mustafa, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Cetinkaya] Tuğba, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Aritürk] Nurşen, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation. © 2015, Springer Science+Business Media Dordrecht.en_US
dc.identifier.doi10.1007/s10792-015-0097-z
dc.identifier.endpage183en_US
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue2en_US
dc.identifier.pmid26115695
dc.identifier.scopus2-s2.0-84933544000
dc.identifier.scopusqualityQ2
dc.identifier.startpage179en_US
dc.identifier.urihttps://doi.org/10.1007/s10792-015-0097-z
dc.identifier.volume36en_US
dc.identifier.wosWOS:000373181000004
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherSpringer Netherlandsen_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.relation.journalInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAl-Scanen_US
dc.subjectAnterior Chamber Depthen_US
dc.subjectAxial Lengthen_US
dc.subjectOptical Biometryen_US
dc.titleThe Effect of Pupil Dilation on Al-Scan Biometric Parametersen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files