Publication: Poly-Axial Screw Removal
| dc.authorscopusid | 34772171800 | |
| dc.authorscopusid | 57206284748 | |
| dc.authorscopusid | 23059360600 | |
| dc.authorscopusid | 14519040600 | |
| dc.authorscopusid | 57513867000 | |
| dc.authorscopusid | 7003813199 | |
| dc.contributor.author | Ulus, A. | |
| dc.contributor.author | Kaan Kaya, A.H. | |
| dc.contributor.author | Bayri, Y. | |
| dc.contributor.author | Daǧçinar, A. | |
| dc.contributor.author | Sataloglu, H. | |
| dc.contributor.author | Şenel, A. | |
| dc.date.accessioned | 2020-06-21T14:48:29Z | |
| dc.date.available | 2020-06-21T14:48:29Z | |
| dc.date.issued | 2010 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Ulus] Aykan, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Kaan Kaya] Hilmi Hilmî, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bayri] Yasar, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Daǧçinar] Adnan, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Sataloglu] H., Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Şenel] Alparslan, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | As the use of instrumentation in spinal surgery has become common, the need for revision surgery has increased. During revision surgery one of the most difficult steps is removal of poly-axial pedicle screws, especially if no suitable revision set is available. We describe here an easy method for poly-axial screw removal. Leaving or placing a small piece of rod, attached firmly by a nut, tightens the head of the poly-axial screw. It can no longer move freely from the distal part of the screw and the screw can be removed by turning it counterclockwise with a big clamp or needle driver, which is available in almost every surgery set. | en_US |
| dc.identifier.doi | 10.1055/s-0029-1246139 | |
| dc.identifier.endpage | 109 | en_US |
| dc.identifier.issn | 0044-4251 | |
| dc.identifier.issn | 1438-9746 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.pmid | 20135585 | |
| dc.identifier.scopus | 2-s2.0-77952264642 | |
| dc.identifier.startpage | 108 | en_US |
| dc.identifier.uri | https://doi.org/10.1055/s-0029-1246139 | |
| dc.identifier.volume | 71 | en_US |
| dc.identifier.wos | WOS:000277400800012 | |
| dc.language.iso | en | en_US |
| dc.publisher | Georg Thieme Verlag KG | en_US |
| dc.relation.ispartof | Zentralblatt für Neurochirurgie | en_US |
| dc.relation.journal | Central European Neurosurgery | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Poly-Axial Screw | en_US |
| dc.subject | Screw Failure | en_US |
| dc.subject | Screw Removal | en_US |
| dc.title | Poly-Axial Screw Removal | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
