Publication:
Kemik Simanlarının Mini-vida Stabilitesi Üzerine Etkisi: İn Vitro Çalışma

dc.contributor.advisorTürk, Tamer
dc.contributor.authorYerlikaya, Canan
dc.date.accessioned2020-07-21T21:59:19Z
dc.date.available2020-07-21T21:59:19Z
dc.date.issued2016
dc.departmentOMÜ, Sağlık Bilimleri Enstitüsü, Ortodonti Anabilim Dalıen_US
dc.departmentSağlık Bilimleri Enstitüsü / Ortodonti Ana Bilim Dalı
dc.descriptionTez (doktora) -- Ondokuz Mayıs Üniversitesi, 2016en_US
dc.descriptionLibra Kayıt No: 88694en_US
dc.description.abstractAmaç: Bu çalışmasının amacı ortodontik mini-vidaların stabilitesinde kemik simanlarının etkisini in-vitro olarak incelemektir. Materyal ve Metot: Çalışmamızda iki farklı mini-vida, Dewimed ve Sydney, kullanıldı. Mini-vidalar ile koyun humerus kemiğinin 'proksimal metafizi' bölgesinde yerleştirildi. 30 Dewimed mini-vida ve 30 Sydney mini-vida rehber oluklar açılarak kemiğe yerleştirildi. 30 Dewimed mini-vida vidalama öncesi rehber oluklar açılarak ve rehber oluklara kemik simanı konularak kemiğe yerleştirildi. 30 Sidney mini-vida rehber oluklar hazırlandıktan kemik bloğa yerleştirilmiştir ve sonrasında kemik simanı vidanın kanülüne enjekte edildi. Her bir grup, mini-vidaların stabilitesini değerlendirmek amacıyla, iki eşit alt gruba ayrılarak, çıkarma tork değerleri ve pull-out değerleri ölçüldü. Bulgular: Her iki mini-vidanın siman uygulanmış ve uygulanmamış çıkarma tork ve pull-out değerleri kendi içlerinde karşılaştırıldığında istatistiksel olarak önemli fark bulunmadı (P>0,0083). Dewimed mini-vidanın siman uygulanmış ve uygulanmamış tork değerlerinin Sydney mini-vidanın siman uygulanmış ve uygulanmamış tork değerlerinden istatistiksel olarak daha büyük olduğu izlendi (P<0,0083). Sydney mini-vidanın siman uygulanmış ve uygulanmamış pull-out değerlerinin Dewimed mini-vidanın siman uygulanmış ve uygulanmamış pull-out değerlerinden istatistiksel olarak daha büyük olduğu izlendi (P<0,0016). Sonuç: Bu çalışmanın bulguları ışığında, kemik simanlarının mini-vida stabilitesi üzerinde etkisi olmadığı sonucuna ulaşabiliriz. Anahtar Kelimeler: Çıkarma torku; kemik simanı; mini-vida; pull-out; stabilite.
dc.description.abstractAim: The purpose of this study was the in-vitro evaluation of the effect of bone cement on the stability of mini-screws. Material and Methods: Two different mini-screws, Dewimed and Sydney, were used in this study. Mini-screws were inserted into the 'proximal metaphysis' of sheep humerus bone. Thirty Dewimed and 30 Sydney mini-screws were inserted into the bone after pre-drilling without any cement application. Thirty Dewimed mini-screws were inserted into the pre-drilling hole which had been filled with cement. Thirty Sydney mini-screws were inserted after pre-drilling and subsequently bone cement was injected into the cannula of the mini-screw extending from the head to the lateral port holes. Each group was divided into two subgroups to measure the removal torque and the pull-out values for the evaluation of mini-screw stability. Results: Application and non-application of bone cement did not show any significant difference for both mini-screw types (P>0.0083). Removal torque values of Dewimed mini-screws, application and non-application of cement, were significantly higher than that of the Sydney mini-screws (P>0.0083). Pull-out values of Sydney mini-screws, application and non-application of cement, were significantly higher than that of the Dewimed mini-screws (P>0.0016). Conclusion: According to the results of this study it can be concluded that the application of bone cement did not affect the stability of mini-screws. Key Words: Bone cement;mini-screw; pull-out; removal torque; stability.en_US
dc.formatVIII, 56 y. : şekil, tablo ; 30 sm.en_US
dc.identifier.endpage66
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=Br_XTptK8CZ70f0JGX9xEkJ4g4cFe2YmbHajpX5GE0knrdrql01kxaKQuwnBBlQO
dc.identifier.urihttp://libra.omu.edu.tr/tezler/88694.pdf
dc.identifier.yoktezid424853
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Sağlık Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliği
dc.subjectDental Bonding
dc.subjectDental Çimentolar
dc.subjectKemik Vidaları
dc.subjectOrtodonti
dc.subjectDentistryen_US
dc.subjectIn Vitro
dc.subjectDental Bondingen_US
dc.subjectDental Cementsen_US
dc.subjectBone Screwsen_US
dc.subjectOrthodonticsen_US
dc.subjectIn Vitroen_US
dc.subject.otherTEZ DOK Y35k 2016en_US
dc.titleKemik Simanlarının Mini-vida Stabilitesi Üzerine Etkisi: İn Vitro Çalışma
dc.titleEffects of Bone Cement on the Stability of Miniscrews: In-Vitro Studyen_US
dc.typeDoctoral Thesisen_US
dspace.entity.typePublication

Files