Publication:
Evaluation of the BioFire FilmArray Pneumonia Panel for Lower Respiratory Tract Specimens in Tertiary Care Medical Centre

dc.authorscopusid57667174800
dc.authorscopusid36479754000
dc.authorscopusid59656190300
dc.authorscopusid57193201285
dc.authorscopusid24829334600
dc.authorscopusid6701577980
dc.authorwosidÇınar, Canberk/Isa-1286-2023
dc.authorwosidGur Vural, Demet/Jgn-6160-2023
dc.authorwosidTanriverdi Cayci, Yeliz/Aaa-5191-2020
dc.authorwosidÇinar, Canberk/Isa-1286-2023
dc.contributor.authorCinar, Canberk
dc.contributor.authorCayci, Yeliz Tanriverdi
dc.contributor.authorDastan, Muhammed Samed Emre
dc.contributor.authorVural, Demet Gur
dc.contributor.authorBilgin, Kemal
dc.contributor.authorBirinci, Asuman
dc.contributor.authorIDTanriverdi Çaycı, Yeliz/0000-0002-9251-1953
dc.contributor.authorIDÇinar, Canberk/0000-0002-8355-7749
dc.date.accessioned2025-12-11T01:15:29Z
dc.date.issued2025
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Cinar, Canberk; Cayci, Yeliz Tanriverdi; Vural, Demet Gur; Bilgin, Kemal; Birinci, Asuman] Ondokuz Mayis Univ, Fac Med, Dept Med Microbiol, Samsun, Turkiye; [Dastan, Muhammed Samed Emre] Niksar State Hosp Tokat, 3 Hizir Sok,Hizir Sok 3, TR-60600 NiksarTokat, Turkiyeen_US
dc.descriptionTanriverdi Çaycı, Yeliz/0000-0002-9251-1953; Çinar, Canberk/0000-0002-8355-7749en_US
dc.description.abstractLower respiratory tract infections are an important cause of morbidity and mortality. Identification of infectious etiology is very important for specific treatment. In addition to routine methods in diagnosis, polymerase chain reaction-based tests have been used. By identifying pathogenic organisms and specific antibiotic resistance markers earlier than routine methods, these tests have the potential to accurately detect agent and reduce the duration of antibiotic therapy. The aim of this study is to show that the use of multiplex polymerase chain reaction-based method may be useful in early diagnosis and specific treatment. In this study, 283 lower respiratory tract samples sent to Ondokuz May & imath;s University Faculty of Medicine Hospital Molecular Microbiology Laboratory between 01/08/2021-01/04/2023 were retrospectively analyzed. Lower respiratory tract samples were studied with BioFire (R) FilmArray Pneumonia Panel plus (BioMe<acute accent>rieux, France). The lower respiratory tract samples of the patients sent at the same time were planted on 5% sheep blood agar, chocolate and EMB agar and incubated at 36 degrees C for 24 h. Identification of bacteria was performed by Vitek MS. Antibiotic sensitivities were studied in Vitek2 Compact automated systems. Two hundred and eighty-three patient samples were included in the study; 156 (55%) of the samples were bronchoalveolar lavage samples and 127 (45%) are sputum samples. When panel and culture results were compared, compatible results were found in 70%. In 88 (61%) of the patients with no growth in culture, no agent was detected as a result of the panel or only viral agents were detected. MecA/C and MREJ resistance genes were detected in 26% of 46 patients with S. aureus detected in the pneumonia panel. CTX-M resistance gene was detected in a total of 28 samples in the pneumonia panel. The OXA-48 carbapenem resistance gene was detected in 14 samples. In our study, it has been shown that Multiplex-PCR has an important place in detecting atypical bacterial and viral factors that do not grow in routine culture in lower respiratory tract infections. In addition, by identifying the resistance genes in the detected bacterial agents, it will contribute to the correct initiation of empirical treatment and to prevent unnecessary antibiotic use in lower respiratory tract diseases where viral factors play a role.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.7546/CRABS.2025.02.11
dc.identifier.endpage260en_US
dc.identifier.issn1310-1331
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85218953968
dc.identifier.scopusqualityQ3
dc.identifier.startpage253en_US
dc.identifier.urihttps://doi.org/10.7546/CRABS.2025.02.11
dc.identifier.urihttps://hdl.handle.net/20.500.12712/42413
dc.identifier.volume78en_US
dc.identifier.wosWOS:001433477800011
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherPubl House Bulgarian Acad Scien_US
dc.relation.ispartofComptes Rendus De L'Académie Bulgare Des Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPneumoniaen_US
dc.subjectMultiplex PCRen_US
dc.subjectRespiratory Pathogenen_US
dc.titleEvaluation of the BioFire FilmArray Pneumonia Panel for Lower Respiratory Tract Specimens in Tertiary Care Medical Centreen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files