Publication:
Diagnostic Accuracy of Endoscopy for the Detection of Isthmuses of Mandibular Molar Teeth Using Micro-CT as Reference

dc.authorscopusid8731395200
dc.authorscopusid56471565700
dc.authorscopusid57212195460
dc.authorscopusid57210663500
dc.authorscopusid8514094700
dc.authorwosidKeskin, Cangul/Aca-8702-2022
dc.authorwosidKeleş, Ali/J-5897-2015
dc.contributor.authorKeleş, Ali
dc.contributor.authorKeskin, Cangül
dc.contributor.authorAlqawasmi, Rawan
dc.contributor.authorGündüz, Kaan
dc.contributor.authorAydemir, Hikmet
dc.contributor.authorKeles, Ali
dc.contributor.authorKeskin, Cangul
dc.contributor.authorAlqawasmi, Rawan
dc.contributor.authorGunduz, Kaan
dc.contributor.authorAydemir, Hikmet
dc.contributor.authorID0000-0003-2835-767Xen_US
dc.contributor.authorID0000-0001-8990-4847en_US
dc.contributor.authorID0000-0002-1544-6844en_US
dc.contributor.authorID0000-0002-0464-1978en_US
dc.contributor.authorID0000-0001-5750-8831en_US
dc.contributor.authorID0000-0003-2835-767X
dc.contributor.authorIDAlqawasmi, Rawan/0000-0002-1544-6844
dc.contributor.authorIDKeskin, Cangül/0000-0001-8990-4847
dc.date.accessioned2022-05-31T07:20:50Z
dc.date.available2022-05-31T07:20:50Z
dc.date.issued2021
dc.departmentOMÜ, Diş Hekimliği Fakültesi, Ağız Diş ve Çene Radyolojisi
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Keles, Ali; Keskin, Cangul; Alqawasmi, Rawan; Aydemir, Hikmet] Ondokuz Mayis Univ, Fac Dent, Dept Endodont, Samsun, Turkey; [Gunduz, Kaan] Ondokuz Mayis Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Samsun, Turkeyen_US
dc.descriptionESCI
dc.descriptionAli/0000-0003-2835-767X; Alqawasmi, Rawan/0000-0002-1544-6844; Keskin, Cangül/0000-0001-8990-4847en_US
dc.description.abstractPurpose The aim of this study was to evaluate the efficacy of endoscopic visualisation to detect the presence and type of isthmuses within the mesial root canals of mandibular first molar teeth compared with micro-computed tomography (micro-CT) images as reference. Materials and Methods Thirty-two mesial roots of mandibular first molars presenting isthmuses were selected based on micro-CT scans. In all, 12 type I and 20 band-shaped isthmuses were collected. The specimens were mounted in the posterior socket of dental phantom manikin for endoscopic visualisation. The ability of endoscopes to visualize the presence of isthmuses and distinguish the type of isthmuses was compared. Micro-CT images of the specimens were used as references. Data were analyzed using Fisher's exact tests. Results Sensitivity of endoscope to detect isthmuses were also calculated for each isthmus type. In 37.5% of the samples, isthmus presence was correctly diagnosed via orthograde endoscopic visualization. Type I istmuses were significantly more detected than band-shaped isthmuses (P<0.05). Endoscope showed higher sensitivity to detect type I isthmus than band-shaped isthmus. Conclusion The endodontic endoscope could detect type I isthmuses more accurately than band-shaped isthmuses.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey-TUBITAK [117S139]en_US
dc.description.sponsorshipThis study was supported by the Scientific and Technological Research Council of Turkey-TUBITAK (grant no. 117S139).en_US
dc.description.urihttps://pubmed.ncbi.nlm.nih.gov/33937760/
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.citationKELEŞ A,KESKİN C,ALQAWASMİ R,GÜNDÜZ K,AYDEMİR H (2021). Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference. European oral research (Online), 55(1), 34 - 38. Doi: 10.26650/eor.20210065.en_US
dc.identifier.doi10.26650/eor.20210065
dc.identifier.endpage38en_US
dc.identifier.issn2630-6158
dc.identifier.issn2630-6158
dc.identifier.issn2651-2823
dc.identifier.issn2651-2823
dc.identifier.issue1en_US
dc.identifier.pmid33937760
dc.identifier.scopus2-s2.0-85131194892
dc.identifier.scopusqualityQ3
dc.identifier.startpage34en_US
dc.identifier.trdizinid426589
dc.identifier.urihttps://doi.org/10.26650/eor.20210065
dc.identifier.urihttps://doi.org/10.26650/eor.20210065
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/426589/diagnostic-accuracy-of-endoscopy-for-the-detection-of-isthmuses-of-mandibular-molar-teeth-using-micro-ct-as-reference
dc.identifier.urihttps://hdl.handle.net/20.500.12712/33288
dc.identifier.volume55en_US
dc.identifier.wosWOS:000618359700006
dc.institutionauthorKeleş, Ali
dc.institutionauthorKeskin, Cangül
dc.institutionauthorAlqawasmi, Rawan
dc.institutionauthorGündüz, Kaan
dc.institutionauthorAydemir, Hikmet
dc.language.isoenen_US
dc.publisherIstanbul Univ Press, Istanbul Univ Rectorateen_US
dc.relation.ispartofEuropean Oral Researchen_US
dc.relation.journalEuropean oral research (Online)en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIsthmusen_US
dc.subjectMicro-Computed Tomographyen_US
dc.subjectEndoscopic Visualizationen_US
dc.subjectRoot Canal Anatomyen_US
dc.subject.otherDentistry, Oral Surgery & Medicine
dc.titleDiagnostic Accuracy of Endoscopy for the Detection of Isthmuses of Mandibular Molar Teeth Using Micro-CT as Referenceen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
f562922b-885d-4b05-ad41-c3e962fd3631.pdf
Size:
479.98 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: