Publication:
Effects of Fluorosis on the Shear Bond Strength of Orthodontic Brackets Bonded with a Self-Etching Primer

dc.authorscopusid15759747100
dc.authorscopusid16639812900
dc.authorscopusid36547366100
dc.authorscopusid8542671800
dc.authorscopusid8542671700
dc.contributor.authorIsci, D.
dc.contributor.authorŞahin Saǧlam, A.M.
dc.contributor.authorAlkiş, H.
dc.contributor.authorElekdaǧ-Türk, S.
dc.contributor.authorTürk, T.
dc.date.accessioned2020-06-21T14:40:31Z
dc.date.available2020-06-21T14:40:31Z
dc.date.issued2011
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Isci] Devrim, Department of Orthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Şahin Saǧlam] Aynur Medine, Inci-Dent Dental Hospital, Isparta, Turkey; [Alkiş] Hüseyin, Department of Orthodontics, Süleyman Demirel Üniversitesi, Isparta, Isparta, Turkey; [Elekdaǧ-Türk] Selma T., Department of Orthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Türk] Tamer, Department of Orthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe aim of this study was to compare the shear bond strength (SBS) of brackets bonded to fluorosed and non-fluorosed teeth with self-etching primer (SEP) and phosphoric acid (PA). The study involved 40 mildly fluorosed [Thylstrup-Fejerskov (TFT) Index = 1-3] and 40 non-fluorosed human premolar teeth. The fluorosed and non-fluorosed teeth were randomly divided into two subgroups. In the first subgroup, 37 per cent PA was applied for 30 seconds and in the second, a SEP (Transbond Plus) was used. The brackets were bonded with light-cure adhesive paste (Transbond XT) and cured for 20 seconds. The SBSs were measured after 1000 thermocyclies. Two-way analysis of variance, Tukey's multiple comparison test, and Weibull analysis were used for the evaluation of SBS values. Bond failure locations were determined with the adhesive remnant index (ARI) and were compared with the Kruskal-Wallis and Mann-Whitney U-tests. The mean SBS was 9.01 MPa for the fluorosed teeth bonded with SEP. This value was significantly different from those of fluorosed teeth etched with PA (15.22 MPa) and non-fluorosed teeth conditioned with SEP (12.95 MPa) and PA (15.37 MPa). The ARI scores of the fluorosed teeth conditioned with SEP were significantly lower than those of non-fluorosed teeth conditioned with SEP or PA. The results of this in vitro study suggest that there are no differences in the SBS of orthodontic brackets between mildly fluorosed and non-fluorosed enamel etched with 37 per cent PA for 30 seconds. The SEP showed lower SBS values for orthodontic brackets bonded to mildly fluorosed enamel. The findings provide some evidence that routine clinical use of a SEP to bond brackets to mildly fluorosed teeth cannot be supported. © The Author 2010.en_US
dc.identifier.doi10.1093/ejo/cjq063
dc.identifier.endpage166en_US
dc.identifier.issn0141-5387
dc.identifier.issn1460-2210
dc.identifier.issue2en_US
dc.identifier.pmid20841314
dc.identifier.scopus2-s2.0-79956066165
dc.identifier.scopusqualityQ1
dc.identifier.startpage161en_US
dc.identifier.urihttps://doi.org/10.1093/ejo/cjq063
dc.identifier.volume33en_US
dc.identifier.wosWOS:000288806900009
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherOxford University Pressen_US
dc.relation.ispartofEuropean Journal of Orthodonticsen_US
dc.relation.journalEuropean Journal of Orthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffects of Fluorosis on the Shear Bond Strength of Orthodontic Brackets Bonded with a Self-Etching Primeren_US
dc.typeArticleen_US
dspace.entity.typePublication

Files