Publication: Potentiometric Detection of Monovalent Anions Separated by Ion Chromatography using All Solid-State Contact PVC Matrix Membrane Electrode
| dc.contributor.author | Isildak, I | |
| dc.date.accessioned | 2020-06-21T15:50:43Z | |
| dc.date.available | 2020-06-21T15:50:43Z | |
| dc.date.issued | 1999 | |
| dc.department | OMÜ | en_US |
| dc.department-temp | Ondokuz Mayis Univ, Fac Sci, Dept Chem, TR-55100 Kurupelit, Turkey -- | en_US |
| dc.description.abstract | An all solid-state contact tubular PVC-matrix membrane electrode has been applied for potentiometric detection of inorganic and organic monovalent anions using phosphate and hydrogen phosphate eluents at low concentrations. This is a "monovalent detection method" as the selectivity of the electrode towards monovalent anions results in some other anions being undetected unless the concentration of those other anions is higher than 10(-3) mol dm(-3) in the sample solution injected. It takes only eight minutes to complete the separation with a good resolution. Theoretical and practical considerations are discussed, and in particular, sensitivity, linearity, detection limit and dynamic behaviour are presented. The use of an all solid-state contact bromide-selective electrode as a detector offers so far the best simultaneous sensitivity toward all anions when compared with other detection methods. Determination of Cl- and NO3- ions in river, rain and drinking water samples without any further sample preconcentration has been successfully achieved. The detection limit is sub-ppb for most of anions in a 20 mu L injection volume. | en_US |
| dc.identifier.doi | 10.1007/BF02467567 | |
| dc.identifier.endpage | 342 | en_US |
| dc.identifier.issn | 0009-5893 | |
| dc.identifier.startpage | 338 | en_US |
| dc.identifier.uri | https://doi.org/10.1007/BF02467567 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/22447 | |
| dc.identifier.volume | 49 | en_US |
| dc.identifier.wos | WOS:000079216700018 | |
| dc.language.iso | en | en_US |
| dc.publisher | Springer Heidelberg | en_US |
| dc.relation.journal | Chromatographia | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Column Liquid Chromatography | en_US |
| dc.subject | Ion Chromatography | en_US |
| dc.subject | Monovalent Anions Determination | en_US |
| dc.subject | Potentiometric Detection | en_US |
| dc.subject | Ion Selective PVC-Matrix Electrode | en_US |
| dc.title | Potentiometric Detection of Monovalent Anions Separated by Ion Chromatography using All Solid-State Contact PVC Matrix Membrane Electrode | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
