Publication: Bond Strength of Total-Etch Dentin Adhesive Systems on Peripheral and Central Dentinal Tissue: A Microtensile Bond Strength Test
| dc.authorscopusid | 13406980700 | |
| dc.authorscopusid | 13406273200 | |
| dc.contributor.author | Yeşilyurt, C. | |
| dc.contributor.author | Bulucu, B. | |
| dc.date.accessioned | 2020-06-21T09:23:15Z | |
| dc.date.available | 2020-06-21T09:23:15Z | |
| dc.date.issued | 2006 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Yeşilyurt] Cemal, Department of Restorative Dentistry, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Bulucu] Bilinç, Department of Restorative Dentistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | Objective: The purpose of this study was to evaluate the microtensile bond strength (μ TBS) of four total-etch adhesives [Excite (EB), Prime & Bond NT (PBNT), Single Bond (SB), and One Coat Bond (OCB)] by comparing them to five self-etching adhesives (Clearfil SE Bond (CSEB), Xeno III (X III), Prompt L-Pop (PLP), AQ Bond (AQB), and Tyrian/One Step plus (TOSP)] at different dentinal areas. In addition the interface between the adhesive resins and dentin was examined using scanning electron microscopy (SEM). Methods and Materials: Superficial occlusal dentin of extracted human molars was exposed and finished with wet 800-grit silicon carbide paper. A block of composite resin was then bonded to the molar samples with the above adhesives according to the manufacturers' instructions. After 24 hours in water at 37°C, the specimens were sectioned into 1 mm thick slices and divided into two regional subgroups according to their relationship to pulp tissue using visual criteria: pulp center and pulp periphery. The slices were then trimmed for the microtensile bond test and subjected to a tensile force and crosshead speed of 1 mm/min. Two-way analysis of variance was performed for statistical analyses. In addition the bond strengths for nine adhesive systems for each dentinal area were compared using the Post-Hoc test. The resin-dentin interfaces for each adhesive system were observed under a SEM. Results: Mean μ TBS ranged from (25.2 MPa) for TOSP to (48.9 MPa) for PBNT. The bond strengths of total-etch adhesive systems were not significantly different, and were higher than self-etch adhesive systems, except for CSEB (p<0.05). No significant regional difference was observed for all of the nine adhesive systems (p>0.05). SEM observation showed there is not a standard hybridization for adhesive systems. Conclusion: Different dentinal areas may not exhibit as great an influence on bond strengths using new adhesive systems. | en_US |
| dc.identifier.endpage | 14 | en_US |
| dc.identifier.issn | 1526-3711 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.pmid | 16685292 | |
| dc.identifier.scopus | 2-s2.0-33646438819 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 1 | en_US |
| dc.identifier.volume | 7 | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Jaypee Brothers Medical Publishers (P) Ltd | en_US |
| dc.relation.ispartof | Journal of Contemporary Dental Practice | en_US |
| dc.relation.journal | Journal of Contemporary Dental Practice | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Adhesive Systems | en_US |
| dc.subject | Dentin Area | en_US |
| dc.subject | Microtensile Test | en_US |
| dc.title | Bond Strength of Total-Etch Dentin Adhesive Systems on Peripheral and Central Dentinal Tissue: A Microtensile Bond Strength Test | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
