Publication:
Accuracy of Two Apex-Locating Handpieces in Detecting Simulated Vertical and Horizontal Root Fractures

dc.authorscopusid6602373062
dc.authorscopusid8945730700
dc.authorscopusid6602739227
dc.authorscopusid14625009700
dc.authorscopusid6602915612
dc.contributor.authorTopuz, Ö.
dc.contributor.authorUzun, Ö.
dc.contributor.authorTinaz, A.C.
dc.contributor.authorBodrumlu, E.
dc.contributor.authorGörgül, G.
dc.date.accessioned2020-06-21T15:14:44Z
dc.date.available2020-06-21T15:14:44Z
dc.date.issued2008
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Topuz] Özgür, Department of Endodontics and Conservative Treatment, Gazi Üniversitesi, Ankara, Ankara, Turkey; [Uzun] Özgür, Department of Endodontics and Conservative Treatment, Gazi Üniversitesi, Ankara, Ankara, Turkey; [Tinaz] Ali Cemal, Department of Endodontics and Conservative Treatment, Gazi Üniversitesi, Ankara, Ankara, Turkey; [Bodrumlu] Emre H., Department of Operative Dentistry and Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Görgül] Güliz, Department of Endodontics and Conservative Treatment, Gazi Üniversitesi, Ankara, Ankara, Turkeyen_US
dc.description.abstractThe aim of this study was to evaluate in vitro the effectiveness of TCM Endo V and Tri Auto ZX handpieces in detecting simulated horizontal and vertical root fractures. Forty extracted maxillary incisor teeth were randomly divided into 2 groups as simulated incomplete horizontal and vertical root fractures. Auto reverse and electronic apex locator functions of the 2 handpieces were used in both groups. Repeated measures of analysis test and pairwise comparisons were used for statistical analyses. Both handpieces detected the root fractures in an acceptable range. Furthermore, electronic apex locator function of both devices was more efficient in the process than auto reverse function. © 2008 American Association of Endodontists.en_US
dc.identifier.doi10.1016/j.joen.2007.12.018
dc.identifier.endpage313en_US
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.issue3en_US
dc.identifier.pmid18291283
dc.identifier.scopus2-s2.0-39049157675
dc.identifier.scopusqualityQ1
dc.identifier.startpage310en_US
dc.identifier.urihttps://doi.org/10.1016/j.joen.2007.12.018
dc.identifier.volume34en_US
dc.identifier.wosWOS:000253790200014
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherElsevier Science Incen_US
dc.relation.ispartofJournal of Endodonticsen_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectApex Locatoren_US
dc.subjectHorizontal Root Fractureen_US
dc.subjectVertical Root Fractureen_US
dc.titleAccuracy of Two Apex-Locating Handpieces in Detecting Simulated Vertical and Horizontal Root Fracturesen_US
dc.typeArticleen_US
dspace.entity.typePublication