Show simple item record

dc.contributor.authorTaşdemir, Tamer
dc.contributor.authorİnan, Uğur
dc.contributor.authorAydemir, Hikmet
dc.date.accessioned2020-06-21T10:26:27Z
dc.date.available2020-06-21T10:26:27Z
dc.date.issued2002
dc.identifier.issn1300-9044
dc.identifier.issn1300-9044
dc.identifier.urihttps://app.trdizin.gov.tr/publication/paper/detail/TVRjd056VTE=
dc.identifier.urihttps://hdl.handle.net/20.500.12712/7667
dc.description.abstractBu çalışmada System-B ısı kaynağı kullanılarak, devamlı ısı ile obturasyon tekniğinden yararlanılarak doldurulan dişlerdeki, apikal sızıntı miktarı, kanal patı varlığında ve yokluğunda incelendi ve lateral kondensasyon tekniğiyle karşılaştırıldı. Çalışmada 40 adet çekilmiş alt küçük azı dişi kullanıldı. Kanallar step-back tekniğiyle prepare edildi ve dişler, herbiri rastgele seçilmiş 10 dişten oluşan üç deney grubuna ayrıldı. Geriye kalan 10 diş kontrol amacıyla kullanıldı. Dişler doldurulup çini mürekkebinde bekletildi. Daha sonra şeffaflaştırılan dişlerdeki lineer boya sızıntı miktarı stereomikroskopta incelendi ve veriler istatistiksel analize tabi tutuldu. Bu çalışmadan elde edilen sonuçlar, devamlı ısıyla obturasyon tekniğinde kanal patı kullanıldığında, lateral kondensasyon tekniğiyle farklı olmayan bulgular elde edilirken, kanal patı kullanılmadığında daha fazla sızıntı oluştuğunu gösterdi.en_US
dc.description.abstractIn this study, the apical microleakage of continuous wave of condensation technique by using System-B heat source was investigated and compared with the lateral condensation technique. In this study ,40 extracted mandibular premolars were used. The root canals were cleaned and shaped by using step-back technique and the teeth were randomly divided into 3 groups of 10 teeth in each group. Remaining 10 teeth were served as controls. The teeth were obturated and suspended in black india ink. Then the teeth were cleared and linear dye leakage was evaluated by using a stereomicroscope and statistical analysis was made. According to the findings of this study, there was more microleakage in the teeth obturated by System-B heat source without sealer(Group l) - Avarage: 2.91 mm) .In Group 2, in which the teeth were obturated by using System-B heat source and a sealer, the amount of microleakage was 0.72 mm; in Group 3 (lateral condensation) the amount of microleakage was 0.61 mm. According to the results of this study ,in continuous wave of condensation technique when sealer was used, there was no significant difference with lateral condensation in the amount of leakage. When no sealer was used more microleakage was occured.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleDevamlı ısıyla obturasyon tekniğinin kanal patı kullanılarak veya kullanılmadan uygulanmasının apikal sızıntı yönünden değerlendirilmesien_US
dc.title.alternativeThe sealing ability of continuous wave of condensation technique with and without the use of sealersen_US
dc.typeotheren_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume12en_US
dc.identifier.issue2en_US
dc.identifier.startpage1en_US
dc.identifier.endpage5en_US
dc.relation.journalAtatürk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryDiğeren_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record