Basit öğe kaydını göster

dc.contributor.authorTüloğlu, Nuray
dc.contributor.authorBayrak, Şule
dc.contributor.authorErişgin, Züleyha
dc.date.accessioned2020-06-21T10:14:20Z
dc.date.available2020-06-21T10:14:20Z
dc.date.issued2012
dc.identifier.issn1300-9044
dc.identifier.issn1300-9044
dc.identifier.urihttps://app.trdizin.gov.tr/publication/paper/detail/TVRVd01qQXdNQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12712/7010
dc.description.abstractAmaç: Bu çalışmanın amacı, ratlarda subkutanöz olarak yerleştirilen White-Mineral Triokside Aggregate ve BioAggregate’in biyouyumluluklarının histolojik olarak değerlendirilmesidir. Gereç ve Yöntem: 60 adet ratın subkutanöz dokusuna, polietilen tübül içerisinde White-Mineral Trioksit Aggregate ve BioAggregate yerleştirildi ve 7, 15, 30 ve 60. günlerde materyallere karşı gelişen inflamatuar reaksiyon dereceleri ışık mikroskobu altında değerlendirildi. Elde edilen verilerin istatistiksel değerlendirilmesinde Kruskal-Wallis ve Dunn Çoklu Karşılaştırma testleri kullanıldı. Bulgular: Tüm deney periyotlarında, ortalama inflamatuar reaksiyon derecesi açısından gruplar arasında anlamlı bir farklılık saptanmadı (p0,05). İnflamatuar reaksiyon derecesi günlere göre değerlendirildiğinde ise, en düşük inflamatuar reaksiyon derecesinin 60. günde olduğu, ancak aradaki farkın sadece 7. ve 15. günlerde anlamlı olduğu belirlendi (p0,05). Sonuç: BioAggregate’in White-Mineral Triokside Aggregate ile benzer biyouyumluluğa sahip olduğu görülmektedir.en_US
dc.description.abstractPurpose: The aim of this study was to evaluate the biocompatibility of subcutaneous White- Mineral Trioxide Aggregate and BioAggregate implants in rats. Material and Methods: White-Mineral Trioxide Aggregate and BioAggregate were implanted in polyethylene tubules in the subcutaneous tissues of 60 male rats and levels of inflammatory reactions against these materials were assessed on the 7th, 15th, 30th, and 60th days. The statistical analyses of obtained data were performed using Kruskal-Wallis and Dunn‘s Multiple Comparison tests. Results: There was no significant difference between the two groups in terms of average inflammatory reaction levels in all experimental periods (p>0.05). When the levels of inflammatory reactions were evaluated according to day intervals, the lowest inflammatory reaction level was determined on the 60th day, but the difference was only significant with the 7th and 15th days (p<0.05). Conclusion: It is suggested that BioAggregate has similar biocompatibility to White-Mineral Trioxide Aggregate.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleİki farklı kök ucu dolgu materyali tarafından oluşturulan bağ doku reaksiyonlarının değerlendirilmesien_US
dc.title.alternativeEvaluation of the connective tissue reactions to two different Root-End filling materialsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume22en_US
dc.identifier.issue3en_US
dc.identifier.startpage264en_US
dc.identifier.endpage271en_US
dc.relation.journalAtatürk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster