• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Analysis of plate-screw fixation by finite element method in transverse fractures of the tibia diaphysis

Tarih

2016

Yazar

Bayramoğlu, Emre
Tomak, Yılmaz
Çıraklı, Alper
Göçer, Hasan
Gülman, Birol

Üst veri

Tüm öğe kaydını göster

Özet

Amaç: Sonlu Elemanlar Yöntemi ile hasta için en uygun implantın seçilebilmesi ve seçilen implant üzerinde ani ısı değişikliklerinin etkisinin saptanması amaçlanmıştır. Gereç ve Yöntem: Diafiz bölgesi 1 cm düzenli aralıklarla transvers olarak parçalara ayrıldıktan sonra ortaya çıkan kesitler, kemiğin önden ve yandan görünümleriyle bilgisayar ortamında birleştirilerek üç korteksi olan tübüler kemik modeli oluşturuldu. Model üzerinde 8 delikli plak ve 8 adet vida tibianın lateral korteksi üzerine oturacak şekilde yerleştirildi. Plağın tam ortasından transvers bir kırık oluşturulduktan sonra kemik-plak-vida ile oluşan tüm model, matematik model (örgü) haline getirildi. Analiz sonuçları sonlu elemanlar yöntemi kullanılarak değerlendirildi. Bulgular: Kırık hattına proksimaldeki ve distaldeki en yakın 2. delikte ve vida üzerinde gerilme değerinin en fazla olduğu bulundu. Isı farklarını değerlendirdiğimizde de soğuk ortamdaki plak-vida gerilme değerlerinin normal, ancak sıcak ortamdaki gerilme değerlerine göre yüksek olduğu görüldü. Sonuç: Bu yöntem ile cerrahi öncesi plak-vida-kemik üzerindeki gerilme değerleri bulunarak hastaya kullanılabilecek en uygun plak-vida belirlenebilir. Ayrıca sıcak ortamdan soğuk ortama geçtiğinde plak-vida üzerindeki gerilme kuvvetinde artış olduğundan kırılmaların soğuk ortamda daha fazla olduğu söylenebilir
 
Aim: Using the Finite Element Method, it was aimed to select the most appropriate implant for a patient with a transverse tibia diaphysis fracture and to determine the effect of sudden temperature changes on the selected implant. Materials and Methods: After separating the diaphyseal area into transverse pieces at 1 cm regular intervals, the anterior and lateral views of the cross-sections enabled the generation of a computer model of tubular bone with 3 cortices. An 8-hole plate with 8 screws was placed over the lateral cortex of the tibia on the model. After creating a transverse fracture in the exact centre of the plate, the whole model with bone-plate-screw was converted into a mathematical model (mesh). The results of the analysis were evaluated using the finite elements method. Results: The tensile values were found to be greatest on the 2nd holes and screws from the proximal and distal of the fracture line. In the evaluation of temperature changes, the plate-screw tensile values were determined as normal in a cold environment but were seen to be high compared to those of a hot environment. Conclusion: By finding the tensile values on plate-screw-bone with this method preoperatively, the most appropriate plate-screw to be used on the patient can be determined. In addition, as tensile force on the plate-screw increased with transfer from a hot environment to a cold one, it could be said that fractures are more likely to occur in a cold environment
 

Kaynak

Ege Tıp Dergisi

Cilt

55

Sayı

3

Bağlantı

https://app.trdizin.gov.tr/publication/paper/detail/TWpBek9UWXhNUT09
https://hdl.handle.net/20.500.12712/6935

Koleksiyonlar

  • Makale Koleksiyonu [9]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [4706]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.