dc.contributor.author | Kuşderci H. | |
dc.contributor.author | Bariş S. | |
dc.contributor.author | Kelsaka E. | |
dc.contributor.author | Kocamanoğlu S. | |
dc.date.accessioned | 2020-06-21T09:42:09Z | |
dc.date.available | 2020-06-21T09:42:09Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 1300-0578 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/4973 | |
dc.description.abstract | Objective: The aim of this study was to compare the Truview infant EVO2 laryngoscope and the Miller straight blade laryngoscope on hemodynamic effects, laryngeal view and intubation conditions in neonates. Methods: In this prospective randomized study, 100 neonates undergoing surgery under general anesthesia were included into the study. Infants were divided into two groups: Endotracheal intubation was performed with a Truview infant blade (Group VL) or with a Miller 0 blade (Group DL). The hemodynamic parameters (heart rate and mean blood pressure, peripheric oxygen saturation, end-tidal CO2 were recorded at preoperatively, after induction, and 1, 3, 5, 10 min after intubation. Laringoscopic view was assessed with Cormack-Lehane score. Intubation conditions and complications were also recorded. Results: There were no statistical differences among demographic parameters, heart rate, mean blood pressure, peripheral oxygen saturations and Cormack-Lehane scores (p>0.05). Duration of intubation was longer with Truview laryngoscope blade than Miller blade (31.6±7.0 sec vs 19.3±4.5 sec) (p<0.0001). In DL Group, one patient experienced post-extubation hoarseness. Conclusion: It has been found that tracheal intubation with Truview EVO2 infant blade resulted in longer intubation time with similar laryngoscopic view compared to Miller blade in neonates. | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Intubation | en_US |
dc.subject | Neonate | en_US |
dc.subject | Truview EVO2 laryngoscope | en_US |
dc.title | Comparison of truview EVO2 infant laryngoscopy and direct laryngoscopy on hemodynamic parameters and intubation conditions in neonates | en_US |
dc.title.alternative | Yeni?doğanlarda truview EVO2 lari?ngoskop i?le miller bleydli? lari?ngoskopun hemodi?nami? ve entübasyon koşullari yönünden karçilaştirilmasi | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 21 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 119 | en_US |
dc.identifier.endpage | 124 | en_US |
dc.relation.journal | Anestezi Dergisi | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |