Basit öğe kaydını göster

dc.contributor.authorKuşderci H.
dc.contributor.authorBariş S.
dc.contributor.authorKelsaka E.
dc.contributor.authorKocamanoğlu S.
dc.date.accessioned2020-06-21T09:42:09Z
dc.date.available2020-06-21T09:42:09Z
dc.date.issued2013
dc.identifier.issn1300-0578
dc.identifier.urihttps://hdl.handle.net/20.500.12712/4973
dc.description.abstractObjective: The aim of this study was to compare the Truview infant EVO2 laryngoscope and the Miller straight blade laryngoscope on hemodynamic effects, laryngeal view and intubation conditions in neonates. Methods: In this prospective randomized study, 100 neonates undergoing surgery under general anesthesia were included into the study. Infants were divided into two groups: Endotracheal intubation was performed with a Truview infant blade (Group VL) or with a Miller 0 blade (Group DL). The hemodynamic parameters (heart rate and mean blood pressure, peripheric oxygen saturation, end-tidal CO2 were recorded at preoperatively, after induction, and 1, 3, 5, 10 min after intubation. Laringoscopic view was assessed with Cormack-Lehane score. Intubation conditions and complications were also recorded. Results: There were no statistical differences among demographic parameters, heart rate, mean blood pressure, peripheral oxygen saturations and Cormack-Lehane scores (p>0.05). Duration of intubation was longer with Truview laryngoscope blade than Miller blade (31.6±7.0 sec vs 19.3±4.5 sec) (p<0.0001). In DL Group, one patient experienced post-extubation hoarseness. Conclusion: It has been found that tracheal intubation with Truview EVO2 infant blade resulted in longer intubation time with similar laryngoscopic view compared to Miller blade in neonates.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIntubationen_US
dc.subjectNeonateen_US
dc.subjectTruview EVO2 laryngoscopeen_US
dc.titleComparison of truview EVO2 infant laryngoscopy and direct laryngoscopy on hemodynamic parameters and intubation conditions in neonatesen_US
dc.title.alternativeYeni?doğanlarda truview EVO2 lari?ngoskop i?le miller bleydli? lari?ngoskopun hemodi?nami? ve entübasyon koşullari yönünden karçilaştirilmasien_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume21en_US
dc.identifier.issue2en_US
dc.identifier.startpage119en_US
dc.identifier.endpage124en_US
dc.relation.journalAnestezi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US