Basit öğe kaydını göster

dc.contributor.authorBodrumlu E.
dc.contributor.authorKoçak M.M.
dc.contributor.authorHazar Bodrumlu E.
dc.contributor.authorOzcan S.
dc.contributor.authorKoçak S.
dc.date.accessioned2020-06-21T09:38:03Z
dc.date.available2020-06-21T09:38:03Z
dc.date.issued2014
dc.identifier.issn0926-4970
dc.identifier.urihttps://hdl.handle.net/20.500.12712/4863
dc.descriptionPubMed: 24487946en_US
dc.description.abstractAim. Polymerization ability of light-curing devices can affect the light-cured material hardness. The purpose of the present study was to evaluate and compare the hardness of three temporary filling materials that had been light-cured by either a light emitting diode (LED) or a halogen light-curing unit. Methods. The temporary filling materials, First Fill, Voco Clip and Bioplic, were placed in wells in a Teflon plate. The 24 specimens of each material were divided into two groups (N.=12/group) for photo-activation by either of the two light-curing units. The LED or halogen device was applied for 40s to the top surface of each specimen. A Knoop hardness test was performed on the top and bottom surface of each specimen, with five measurements per specimen. Results. The highest hardness values for both the LED and halogen treated groups were observed for First Fill and the lowest values were for Voco Clip in top and bottom surfaces. The hardness obtained for the three materials with the halogen unit were significantly higher than the values obtained with the LED unit in both surfaces (P<0.05). Conclusion. First Fill light-cured temporary material exhibited the highest hardness values on the top and bottom surfaces than Voco Clip and Bioplic temporary materials. The hardness of light-cured temporary filling materials can be affected by the type of light-curing unit.en_US
dc.language.isoengen_US
dc.publisherEdizioni Minerva Medicaen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCuring lightsen_US
dc.subjectDental - Halogensen_US
dc.subjectHardness - Dental restorationen_US
dc.subjectTemporaryen_US
dc.titleComparison of hardness of three temporary filling materials cured by two light-curing devicesen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume63en_US
dc.identifier.issue01.Feben_US
dc.identifier.startpage1en_US
dc.identifier.endpage6en_US
dc.relation.journalMinerva Stomatologicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster