dc.description10th IET International Conference on Developments in Power System Protection, DPSP 2010 -- 29 March 2010 through 1 April 2010 -- Manchester -- 81533en_US
dc.description.abstractThis paper describes two different measuring methodology for calculating fundamental power system frequency (50 - 60 Hz) with high accuracy for numeric protection algorithms. Especially in distance protection, to measure the fundamental power frequency is a vital fact to locate the fault correctly. The problem is complex because the power frequency changes from 49.0 Hz to 51.0 Hz over a wide range for 50 Hz systems. Assuming the frequency of only 50 Hz or 60 Hz may cause under or over reach problem in distance relaying algorithms. Therefore the aim of this paper is to present a high accuracy, with a wide range frequency estimation algorithm for either sinusoid or non-sinusoid signals. The experimental results reported prove that the first method is more accurate than the second one. In this paper, two different calculation procedures are introduced. The first one is curve fitting approach and needs only six samples of the current or voltage signal. The second one is based on auto correlation function of sampled data. The proposed methods are robust for a wide range of sampling frequency, Fs and give more accurate results than the traditional ones.en_US
dc.language.isoengen_US
dc.relation.isversionof10.1049/cp.2010.0327en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectauto correlation function (ACF)en_US
dc.subjectcurve fitting (CF)en_US
dc.subjectFast Fourier Transform (FFT)en_US
dc.subjectFrequency estimationen_US
dc.subjectnon-sinusoidalen_US
dc.titleCalculation of fundamental power frequency for digital relaying algorithmsen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume2010en_US
dc.identifier.issue558 CPen_US
dc.relation.journalIET Conference Publicationsen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster