• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Enstitüler
  • Lisansüstü Eğitim Enstitüsü
  • Yenilenebilir Enerji ve Uygulamaları Ana Bilim Dalı
  • Yüksek Lisans Tez Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Enstitüler
  • Lisansüstü Eğitim Enstitüsü
  • Yenilenebilir Enerji ve Uygulamaları Ana Bilim Dalı
  • Yüksek Lisans Tez Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Güneş enerjili yer çekimi destekli ısı borusunda farklı adyabatik bölge uzunluklarının sistem performansı üzerine etkisinin deneysel araştırılması

Thumbnail

Göster/Aç

Tam Metin / Tez (2.229Mb)

Tarih

2021

Yazar

Shabani, Saba

Üst veri

Tüm öğe kaydını göster

Künye

Shabani, S. (2021). Güneş enerjili yer çekimi destekli ısı borusunda farklı adyabatik bölge uzunluklarının sistem performansı üzerine etkisinin deneysel araştırılması. (Yüksek lisans tezi). Ondokuz Mayıs Üniversitesi, Samsun.

Özet

Bu çalışmada yer çekimi destekli iki fazlı kapalı termosifon tipi ısı borusunda bulunan adyabatik bölge uzunluğunun ısı borusu üzerindeki etkisi deneysel olarak araştırılmıştır. Bunun için 0 cm (a), 5 cm (b), 10 cm (c) ve 15 cm (d) adyabatik zon uzunluklarına sahip dört adet ısı borusu üretilmiştir. Aynı malzeme ve çaptaki a, b, c ve d ısı borularında çalışma sıvısı olarak saf su kullanılmıştır. Sonbaharda ısı boruları güneş enerjisi ile aynı zaman ve koşullarda çalıştırılarak deneysel olarak karşılaştırılmıştır. İki aşamalı deneylerin ilkinde, sadece ısı borusu üzerindeki sıcaklık dağılımları incelenmiştir. İkinci aşamada ise 0,4 litre hacmindeki su ısıtılarak ısı borusu üzerindeki sıcaklık dağılımı incelenmiştir. İlk aşama deneylerinde a, b, c ve d ısı boruları için en yüksek kondansatör sıcaklıkları sırasıyla 96.6 °C, 74.5 °C, 79.8 °C ve 84.8 °C idi. Depodaki suyun ısıtıldığı ikinci aşama deneylerinde, en yüksek tank sıcaklıkları sırasıyla a, b, c ve d ısı borularında 50.1 °C, 47.7 °C, 52.8 °C ve 47.2 °C olarak elde edilmiştir.
 
In this study, the effect of the length of the adiabatic section in the gravity assisted two-phase closed thermosiphon type heat pipe on the heat pipe was investigated experimentally. For this, four heat pipes with adiabatic zone lengths of 0 cm (a), 5 cm (b), 10 cm (c) and 15cm (d) were manufactured. Pure water was used as the working fluid in a, b, c and d heat pipes of the same material and diameter. Heat pipes were actuated under the same time and conditions with solar energy in autumn and compared experimentall y. In the first of the two-stage experiments, only the temperature distributions on the heat pipe were examined. In the second stage, the temperature distribution on the heat pipe was examined by heating water in a volume of 0.4 liters. The highest condenser temperatures for a, b, c and d heat pipes were 96.6 oC, 74.5 oC, 79.8 oC and 84.8 oC, respectively, in the first stage experiments. In the second stage experiments in which the water in the storage was heated, the highest tank temperatures of 50.1 oC, 47.7 oC, 52.8 oC and 47.2 oC were achieved in the heat pipes a, b, c and d respectively.
 

Bağlantı

http://libra.omu.edu.tr/tezler/135758.pdf
https://hdl.handle.net/20.500.12712/33777

Koleksiyonlar

  • Yüksek Lisans Tez Koleksiyonu [9]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.