Construction and response characteristics of a sulfite/hydrogensulfite-selective all-solid-state contact electrode based on the 4-methylpiperidinedithiocarbamate complex of mercury(II)

Tarih

1996

Yazar

Isildak, I
Yigit, C
Bati, H

Üst veri

Tüm öğe kaydını göster

Özet

An all-solid-state contact electrode selective for sulfite/hydrogensulfite was constructed using a wire coated with a mixture of graphite, epoxy and hardener and covered by 4-methylpiperidinedithiocarbamate-mercury(II) complex. Its preparation and the response characteristics were examined. With an optimum thickness of the complex at the surface of the all-solid-state contact (which appears to affect the response time, slope and lifetime), the electrode exhibited a short response time and high selectivity for reducing species, and also was found to be reproducible for 3 weeks when kept in distilled water or dry. For electrodes exposed to solutions containing high levels (0.1 mol dm(-3)) of sulfite/hydrogensulfite or reducing species, e.g., Sn-II or Cu-I, the response was significantly lower. The observed response of the electrode only to reducing species can be attributed to a heterogeneous redox reaction (sulfite in the sample reduces Hg-II to Hg-I at the electrode-sample interface). Under controlled conditions such a heterogeneous redox reaction resulted in a highly selective and reproducible response to reducing species, especially to sulfite/hydrogensulfite. The response of the all-solid-state contact electrode was linear with a slope of -70 +/-5 mV between 0.1 and 5 x 10(-6) mol dm(-3) sulfite/hydrogensulfite concentration and the useful pH range from 0.1 to 1 x 10(-6) mol dm(-3) sulfite/hydrogensulfite was between 3.0 and 9.0. Further, the selectivity of sulfite over iodide, thiocyanate, thiosulfate and bromide was much improved compared with that for a liquid membrane sulfite electrode.

Kaynak

Analyst

Cilt

121

Sayı

12

Bağlantı

https://hdl.handle.net/20.500.12712/22687

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.