Basit öğe kaydını göster

dc.contributor.authorUyanik, A
dc.date.accessioned2020-06-21T15:53:13Z
dc.date.available2020-06-21T15:53:13Z
dc.date.issued1998
dc.identifier.issn1010-7614
dc.identifier.urihttps://hdl.handle.net/20.500.12712/22599
dc.descriptionWOS: 000074905000011en_US
dc.description.abstractA previously reported single-column gas chromatographic separation method was modified for dual detection gas chromatography (TCD + FID) and evaluated for the low concentration analysis of volatile anaesthetics (halothane, isoflurane) and nitrous oxide. It was found that no serious problem occurs in the determination of volatile anaesthetics with FID (<10 ppm), but nitrous oxide introduces lack of sensitivity at lower concentrations with TCD (<40 ppm) in the described analysis method with a 0.25 mi sample loop.en_US
dc.language.isoengen_US
dc.publisherScientific Technical Research Council Turkeyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectgas chromatographyen_US
dc.subjecthalothaneen_US
dc.subjectisofluraneen_US
dc.subjectnitrous oxideen_US
dc.titleGas chromatography in the low concentration determination of nitrous oxide and volatile anaestheticsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume22en_US
dc.identifier.issue3en_US
dc.identifier.startpage267en_US
dc.identifier.endpage271en_US
dc.relation.journalTurkish Journal of Chemistryen_US