Basit öğe kaydını göster

dc.contributor.authorÖzyürek T.
dc.contributor.authorYilmaz K.
dc.contributor.authorUslu G.
dc.date.accessioned2020-06-21T09:04:45Z
dc.date.available2020-06-21T09:04:45Z
dc.date.issued2017
dc.identifier.issn1658-5984
dc.identifier.urihttps://doi.org/10.4103/1658-5984.205123
dc.identifier.urihttps://hdl.handle.net/20.500.12712/2107
dc.description.abstractAim: The aim of this study is to evaluate R-Endo R3 file's resistance to cyclic fatigue in comparison with continuous rotation movement and 'Adaptive Motion' (AM) movement under dynamic model. Materials and Methods: Forty pieces of R-Endo R3 (25.04) files (lot no: 062011) were included in the study. Cyclic fatigue tests were performed with specifically manufactured dynamic cyclic testing device. The device has an artificially prepared canal with 60° curvature angle and 5 mm curvature radius. The canal inner diameter is 1.5 mm and the center of curvature is located 5 mm coronally from the apex. The files were randomly divided into two groups (n = 20) and the following procedures were performed - Group 1: Rotary motion (RM), Group 2: AM. Time to fracture was recorded and the number of cycles to failure for each instrument was obtained. Statistical analyses were performed using Student's t-test. The statistical significant level was set at P < 0.05. Results: AM group had a significantly higher cyclic fatigue resistance compared with RM group (P < 0.001). Conclusion: Within the limitation of the present study, it was found that 'Adaptive Motion' statistically increases the resistance to cyclic fatigue of R-Endo R3 files, manufactured for retreatment. © 2017 Saudi Endodontic Journal Published by Wolters Kluwer - Medknow.en_US
dc.language.isoengen_US
dc.publisherMedknow Publicationsen_US
dc.relation.isversionof10.4103/1658-5984.205123en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAdaptive motionen_US
dc.subjectdynamic cyclic fatigue testen_US
dc.subjectendodonticsen_US
dc.subjectnickel-titaniumen_US
dc.subjectR-Endoen_US
dc.titleEffect of adaptive motion on cyclic fatigue resistance of R-Endo nickel-titanium fileen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume7en_US
dc.identifier.issue2en_US
dc.identifier.startpage82en_US
dc.identifier.endpage86en_US
dc.relation.journalSaudi Endodontic Journalen_US