Basit öğe kaydını göster

dc.contributor.authorElekdag-Turk, Selma
dc.contributor.authorSarac, Y. Sinasi
dc.contributor.authorTurk, Tamer
dc.contributor.authorSarac, Duygu
dc.date.accessioned2020-06-21T15:20:03Z
dc.date.available2020-06-21T15:20:03Z
dc.date.issued2007
dc.identifier.issn0141-5387
dc.identifier.issn1460-2210
dc.identifier.urihttps://doi.org/10.1093/ejo/cjm017
dc.identifier.urihttps://hdl.handle.net/20.500.12712/19953
dc.descriptionElekdag-Turk, Selma/0000-0002-2799-6501en_US
dc.descriptionWOS: 000247471200012en_US
dc.descriptionPubMed: 17513877en_US
dc.description.abstractThe aim of this study was to evaluate different curing times of a light-emitting diode (LED) unit on shear bond strength (SBS) of ceramic brackets bonded to feldspathic porcelain. Ceramic brackets were bonded with a light-cured adhesive to 96 feldspathic porcelain facets. Air-borne particle abrasion was performed using 25 mu m aluminium trioxide (Al2O3) with an air abrasion device from a distance of approximately 10 mm at a pressure of 2.5 bars for 4 seconds, then the porcelain surfaces were etched with 9.6 per cent hydrofluoric acid for 2 minutes. After surface preparation of the porcelain specimens, silane was applied. In groups 1 and 2, the adhesive was cured with a quartz-tungsten-halogen (QTH) unit for 10 and 20 seconds, respectively. The LED was used in the standard mode for 3, 5, and 10 seconds for groups 3, 4, and 5, respectively. For the other three groups, the LED was used in the fast mode for 3, 5, and 10 seconds, respectively. The SBS of the brackets was measured on a universal testing machine. The adhesive remnant index (ARI) scores, damage to the porcelain, and fracture of the ceramic bracket bases were determined. No significant differences were observed for SBS between the eight groups (P = 0.087). There was no significant difference between the groups' ARI scores, porcelain damage, and bracket base fracture (P = 0.340, P = 0.985, and P = 0.340, respectively). There was a greater frequency of ARI scores of 0 for all groups. Fifty per cent of the porcelain facets displayed damage. Nineteen ceramic bracket base fractures were observed. No significant difference was found for the SBS of the groups with QTH and LED units and curing times. It is reliable to use LED with a 3-second curing time since it provided adequate bond strength for ceramic brackets bonded to porcelain surfaces.en_US
dc.language.isoengen_US
dc.publisherOxford Univ Pressen_US
dc.relation.isversionof10.1093/ejo/cjm017en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleThe effect of a light-emitting diode on shear bond strength of ceramic brackets bonded to feldspathic porcelain with different curing timesen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume29en_US
dc.identifier.issue3en_US
dc.identifier.startpage299en_US
dc.identifier.endpage303en_US
dc.relation.journalEuropean Journal of Orthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster