Show simple item record

dc.contributor.authorGueneren, Ethem
dc.contributor.authorEngin, M. Sinan
dc.contributor.authorOezer, Mete
dc.date.accessioned2020-06-21T15:19:00Z
dc.date.available2020-06-21T15:19:00Z
dc.date.issued2007
dc.identifier.issn0148-7043
dc.identifier.urihttps://doi.org/10.1097/SAP.0b013e31802e8ae0
dc.identifier.urihttps://hdl.handle.net/20.500.12712/19798
dc.descriptionGuneren, Ethem/0000-0002-5981-7010;en_US
dc.descriptionWOS: 000248989100012en_US
dc.descriptionPubMed: 17721218en_US
dc.description.abstractWe compared the gap-producing forces, ultimate tensile strength, and slip resistance of a new core suture technique and that of a modified Kessler suture in freshly harvested chicken tendons. Biomechanical trials were carried out using a tensile-strength testing machine. Our technique proved superior to the modified Kessler Suture with respect to its ultimate tensile strength and slip resistance.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.isversionof10.1097/SAP.0b013e31802e8ae0en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjecttendon repairen_US
dc.subjectKessler sutureen_US
dc.subjectcore sutureen_US
dc.subjectbiornechanical studyen_US
dc.subjecttensile strengthen_US
dc.subjectgap-producing forceen_US
dc.titleContribution of a locking cross-stitch to a modified kessler core suture - A new techniqueen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume59en_US
dc.identifier.issue3en_US
dc.identifier.startpage297en_US
dc.identifier.endpage299en_US
dc.relation.journalAnnals of Plastic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US