Basit öğe kaydını göster

dc.contributor.authorBahcivan, Muzaffer
dc.contributor.authorElmali, Muzaffer
dc.contributor.authorKolbakir, Fersat
dc.contributor.authorGol, Kamil
dc.date.accessioned2020-06-21T15:06:44Z
dc.date.available2020-06-21T15:06:44Z
dc.date.issued2009
dc.identifier.issn1302-8723
dc.identifier.issn1308-0032
dc.identifier.urihttps://hdl.handle.net/20.500.12712/18691
dc.description3rd Annual Congress on Updates in Cardiology and Cardiovascular Surgery -- NOV 28-DEC 02, 2007 -- Antalya, TURKEYen_US
dc.descriptionWOS: 000265395700009en_US
dc.descriptionPubMed: 19357054en_US
dc.description.abstractObjective: The term "competitive flow" defines the flow from a partially stenosed native artery that "competes" with the flow from a graft to perfuse the distal tissues. The purpose of our study is to investigate the effects of competitive flow at different degrees of stenosis at common carotid artery, in a rabbit model by measuring both the flow volume and velocity in the various graft. Methods: This prospective experimental study included 33 rabbits, which were divided into three groups: in Group 1, the common carotid arteries were ligated to form a total occlusion, in Group 2, the common carotid arteries were externally incompletely ligated to achieve 50% stenosis, and in Group 3, common carotid arteries were fully patent. The jugular vein was reversed and anastomosed to proximal and distal common carotid arteries using end to side anastomosis technique. Mean arterial pressure, the total flow and velocity were measured in native carotid arteries prior to surgery and in venous grafts 2 months after surgery using Doppler ultrasonography. Statistical analysis was performed using Chi-square test and Kruskal Wallis analysis of variances. Results: There were no differences in graft mean velocity (Group 1 - 16.8 +/- 6.7 cm/sec, Group 2 - 14.1 +/- 6.1 cm/sec and Group 3 - 12.1 +/- 6.7 cm/sec), and mean flow volume (Group 1 - 33.9 +/- 11.5 mL/min, Group 2 - 29.0 +/- 8.3 mL/min, and Group 3 - 24.4 +/- 12.8 mL/min) between groups after surgery (p>0.05 for both). Conclusion: As it was the case in this rabbit model, the reduction of flow volume or velocity in lesser degrees of stenosis in the carotid artery venous bypass grafts is not significant in a statistical perspective. Although in short-term this effect did not create a difference for graft patencies between the groups, it may be important in long-term (Anadolu Kardiyol Derg 2009; 9: 123-7)en_US
dc.language.isoengen_US
dc.publisherTurkish Soc Cardiologyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCompetitive flowen_US
dc.subjectvein graften_US
dc.subjectbypassen_US
dc.subjectarterial occlusionen_US
dc.titleThe effect of competitive flow on both the flow and the velocity in venous grafts in a bypass modelen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume9en_US
dc.identifier.issue2en_US
dc.identifier.startpage123en_US
dc.identifier.endpage127en_US
dc.relation.journalAnadolu Kardiyoloji Dergisi-The Anatolian Journal of Cardiologyen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US