Basit öğe kaydını göster

dc.contributor.authorAkpolat, Tekin
dc.contributor.authorErdem, Emre
dc.contributor.authorAydogdu, Turkan
dc.date.accessioned2020-06-21T14:29:00Z
dc.date.available2020-06-21T14:29:00Z
dc.date.issued2012
dc.identifier.issn1420-4096
dc.identifier.issn1423-0143
dc.identifier.urihttps://doi.org/10.1159/000330719
dc.identifier.urihttps://hdl.handle.net/20.500.12712/16840
dc.descriptionWOS: 000301394400003en_US
dc.descriptionPubMed: 21912183en_US
dc.description.abstractBackground: Encouragement of home blood pressure (BP) monitoring has a great potential to improve hypertension control rates. The purpose of this study was to test validation of the Omron M3 Intellisense (HEM-7051-E) upper arm BP measuring monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2) in stage 3-5 chronic kidney disease (CKD) patients. Methods: 66 patients having CKD stage 3-5 were included in the study. Nine consecutive measurements were made according to the ESH-IP2 protocol. Results: The Omron M3 Intellisense device fulfills the validation criteria of the ESH-1P2 for stage 3-5 CKD patients. Conclusion: Although arterial stiffness can affect accurate BP measurement, there are limited data regarding the use of automated oscillometric devices in CKD. To our knowledge, this is the first study investigating validation of an oscillometric device in stage 3-5 predialysis CKD patients. This study validates the Omron M3 Intellisense upper arm device for stage 3-5 CKD patients. New validation studies investigating other oscillometric sphygmomanometers for CKD patients and involvement of nephrologists in these studies have great potential to increase patient care in CKD. Copyright (C) 2011 S. Karger AG, Baselen_US
dc.language.isoengen_US
dc.publisherKargeren_US
dc.relation.isversionof10.1159/000330719en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectArterial stiffnessen_US
dc.subjectChronic kidney diseaseen_US
dc.subjectHome blood pressure monitoringen_US
dc.subjectHypertensionen_US
dc.subjectOscillometric sphygmomanometersen_US
dc.subjectValidation protocolsen_US
dc.titleValidation of the Omron M3 Intellisense (HEM-7051-E) Upper Arm Blood Pressure Monitor, for Self-Measurement, according to the European Society of Hypertension International Protocol Revision 2010 in a Stage 3-5 Chronic Kidney Disease Populationen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume35en_US
dc.identifier.issue2en_US
dc.identifier.startpage82en_US
dc.identifier.endpage88en_US
dc.relation.journalKidney & Blood Pressure Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster