Basit öğe kaydını göster

dc.contributor.authorBulut, Emel
dc.contributor.authorSahin, Bunyamin
dc.contributor.authorMuglali, Mehtap
dc.contributor.authorBekcioglu, Burak
dc.date.accessioned2020-06-21T14:27:47Z
dc.date.available2020-06-21T14:27:47Z
dc.date.issued2012
dc.identifier.issn1698-6946
dc.identifier.urihttps://doi.org/10.4317/medoral.17570
dc.identifier.urihttps://hdl.handle.net/20.500.12712/16546
dc.descriptionSahin, Bunyamin/0000-0001-8538-8443en_US
dc.descriptionWOS: 000304343300015en_US
dc.descriptionPubMed: 22143725en_US
dc.description.abstractObjective: The purpose of this study is to compare the computer-assisted planimetry and point-counting methods in evaluating the sizes of the mandibular cysts with respect to their agreement and the time required to analyze. Study Design: The surface areas of 46 mandibular cyst lesions on orthopantomograms were estimated using the point-counting and computer-assisted planimetry methods. Three observers evaluated the outlined areas twice, using the point-counting (PC) and computer-assisted planimetry (CAP) methods with an interval of two weeks. In the planimetry technique, digitalized images and ImageJ software were used to measure the surface area of the half mandibles and cysts. The grids were superimposed over the same images and the number of points hitting the interested structures was counted for the point-counting technique. The projection area fraction (PAF) of the cysts within the mandible was estimated using the obtained values by means of the two techniques. Intraclass correlation coefficient was used to assess the level of agreement between the two methods. Inter-rater reliability analysis using the Kappa statistic was performed to determine consistency among raters. Results: CAP and PC techniques showed consistent intra-observer values in all observers. Intraclass correlation between CAP and PC measurements of first, second and third observers were found to be 0.9986, 0.9988 and 0.9994 respectively. The durations of PC technique was 32% higher than the CAP technique. Conclusion: PC and CAP methods were seemed to show sufficient agreement to be used interchangeably. The main disadvantage of the PC analysis is it takes more time than CAP method.en_US
dc.language.isoengen_US
dc.publisherMedicina Oral S Len_US
dc.relation.isversionof10.4317/medoral.17570en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectOrthopantomogramen_US
dc.subjectmandibleen_US
dc.subjectcysten_US
dc.subjectpoint-countingen_US
dc.subjectplanimetryen_US
dc.titleComparison of the planimetry and point-counting methods for the assessment of the size of the mandible cysts on orthopantomogramsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume17en_US
dc.identifier.issue3en_US
dc.identifier.startpageE442en_US
dc.identifier.endpageE446en_US
dc.relation.journalMedicina Oral Patologia Oral Y Cirugia Bucalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster