• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of different power outputs of carbon dioxide laser on bonding between zirconia ceramic surface and resin cement

Tarih

2012

Yazar

Ural, Cagri
Kalyoncuoglu, Elif
Balkaya, Veysel

Üst veri

Tüm öğe kaydını göster

Özet

Objective. The purpose of this in vitro study was to evaluate the influence of different power outputs of a carbon dioxide (CO2) laser on shear bond strength of resin cement to zirconium dioxide-based ceramic. Materials and methods. Fifty zirconium dioxide core specimens (10 mm diameter and 2 mm thickness) were produced and they were embedded in the centers of auto-polymerizing acrylic resin blocks. Ten specimens served as control and no surface treatment was applied. Subsequently specimens were randomly divided into four groups, each containing 10 specimens for surface treatment with CO2 laser with different output power; laser treated with 2 W (Group 2 W), 3 W (Group 3 W), 4 W (Group 4 W) and finally 5 W (Group 5 W). Fifty composite resin discs were fabricated and cemented with adhesive resin cement to the specimen surfaces. A universal test machine was used for shear bond strength test at a crosshead speed 1 mm/min. Data were statistically analyzed by one-way analyses of variance (ANOVA) with Post-Hoc Tukey tests (alpha = 0.05). Results. It was found that the shear bond strength values were affected by power outputs of laser (p < 0.05). Highest shear bond strength values were obtained with group 2 W (21.0 +/- 2.7). Lowest values were obtained with group 5 W (14.4 +/- 1.6). Conclusion. The current study revealed that there was a relationship between laser output power and shear bond strength for zirconium dioxide ceramics. However, output power of the laser and the energy level is a critical factor on micromechanical retention.

Kaynak

Acta Odontologica Scandinavica

Cilt

70

Sayı

6

Bağlantı

https://doi.org/10.3109/00016357.2011.600718
https://hdl.handle.net/20.500.12712/16243

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.