Basit öğe kaydını göster

dc.contributor.authorKocabicak, Ersoy
dc.contributor.authorAygun, Dursun
dc.contributor.authorOzaydin, Ilkay
dc.contributor.authorJahanshahi, Ali
dc.contributor.authorTan, Sonny K. H.
dc.contributor.authorOnar, Musa
dc.contributor.authorTemel, Yasin
dc.date.accessioned2020-06-21T14:04:40Z
dc.date.available2020-06-21T14:04:40Z
dc.date.issued2013
dc.identifier.issn1019-5149
dc.identifier.urihttps://doi.org/10.5137/1019-5149.JTN.8328-13.0
dc.identifier.urihttps://hdl.handle.net/20.500.12712/15692
dc.descriptionCamlidag, Ilkay/0000-0001-6151-1312en_US
dc.descriptionWOS: 000327575300013en_US
dc.descriptionPubMed: 24101315en_US
dc.description.abstractAIM: Subthalamic nucleus (STN) deep brain stimulation (DBS) has become a well-accepted treatment for patients with advanced Parkinson's disease (PD). During surgical planning for DBS, the length of the STN is taken into account and verified during microelectrode recording (MER) intraoperatively. Here, we addressed the question to which extent the length of the STN measured with the 12 weighted MRI in the probe's eye view corresponded with the intraoperatively determined length of the STN with MER. MATERIAL and METHODS: We included 10 consecutive Parkinson's disease patients who underwent STN DBS surgery. The length of the SIN in the probe's eye view mode was calculated along the trajectory of the central MER electrode crossing the STN. RESULTS: Our analysis showed no statistical difference between the length of the SIN measured with the T2 weighted probe's eye view mode and the MER (right STN length 5.8 +/- 0.9 mm MRI vs. 6.3 +/- 0.5 mm gER, p>0.05; left SIN length 5.6 +/- 0.4 mm MRI vs 5.8 +/- 1 mm MER, p>0.05). CONCLUSION: This means that the entry and the exit of the STN can be adequately estimated using the probe's eye view preoperatively.en_US
dc.language.isoengen_US
dc.publisherTurkish Neurosurgical Socen_US
dc.relation.isversionof10.5137/1019-5149.JTN.8328-13.0en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectParkinson's diseaseen_US
dc.subjectSubthalamic nucleusen_US
dc.subjectMicroelectrode recordingen_US
dc.subjectMagnetic resonance imagingen_US
dc.subjectDeep brain stimulationen_US
dc.titleDoes Probe's Eye Subthalamic Nucleus Length on T2W MRI Correspond with Microelectrode Recording in Patients with Deep Brain Stimulation for Advanced Parkinson's Disease?en_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume23en_US
dc.identifier.issue5en_US
dc.identifier.startpage658en_US
dc.identifier.endpage665en_US
dc.relation.journalTurkish Neurosurgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster