dc.contributor.author | Ozgonenel, Okan | |
dc.contributor.author | Karagol, Serap | |
dc.date.accessioned | 2020-06-21T13:56:50Z | |
dc.date.available | 2020-06-21T13:56:50Z | |
dc.date.issued | 2014 | |
dc.identifier.issn | 0378-7796 | |
dc.identifier.issn | 1873-2046 | |
dc.identifier.uri | https://doi.org/10.1016/j.epsr.2014.04.008 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/15034 | |
dc.description | KARAGOL, SERAP/0000-0002-5750-1143 | en_US |
dc.description | WOS: 000337992000007 | en_US |
dc.description.abstract | This paper will propose a cascade of minimum description length criterion with entropy approach along with artificial neural network (ANN) as an optimal feature extraction and selection tool for a wavelet packet transform based transformer differential protection. The proposed protection method provides a reliable and computationally efficient tool for distinguishing between internal faults and inrush currents. The role of minimum description length criterion with entropy approach has been found to improve the efficiency of ANN with the dimensionality reduction of the feature vector. This reduction plays a major role in preventing the redundancy effect that can occur when using several features in an intelligent based monitoring system. (C) 2014 Elsevier B.V. All rights reserved. | en_US |
dc.description.sponsorship | Higher Education Council in TURKEY (a post doctoral study at The University of Nottingham - UK and NC A&T State University USA)Ministry of National Education - Turkey | en_US |
dc.description.sponsorship | This work is supported by Higher Education Council in TURKEY (a post doctoral study at The University of Nottingham - UK, 2013 and NC A&T State University USA, 2013). The authors would like to acknowledge this support. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Science Sa | en_US |
dc.relation.isversionof | 10.1016/j.epsr.2014.04.008 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Entropy approach | en_US |
dc.subject | Minimum description length criterion | en_US |
dc.subject | Inrush current | en_US |
dc.subject | Internal fault | en_US |
dc.subject | Power transformer | en_US |
dc.subject | Wavelet packet analysis | en_US |
dc.title | Transformer differential protection using wavelet transform | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 114 | en_US |
dc.identifier.startpage | 60 | en_US |
dc.identifier.endpage | 67 | en_US |
dc.relation.journal | Electric Power Systems Research | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |