Basit öğe kaydını göster

dc.contributor.authorOmezli, M. M.
dc.contributor.authorTorul, D.
dc.contributor.authorPolat, M. E.
dc.contributor.authorDayi, E.
dc.date.accessioned2020-06-21T13:45:42Z
dc.date.available2020-06-21T13:45:42Z
dc.date.issued2015
dc.identifier.issn1119-3077
dc.identifier.urihttps://doi.org/10.4103/1119-3077.158946
dc.identifier.urihttps://hdl.handle.net/20.500.12712/14156
dc.descriptionTorul, Damla/0000-0003-2323-606Xen_US
dc.descriptionWOS: 000356942700003en_US
dc.descriptionPubMed: 26096234en_US
dc.description.abstractBackground and Aims: The aim of this study was to compare the biomechanical stability of poly-L-lactic acid and titanium screws in the fixation of intracapsular condylar fractures, in 10 polyurethane hemimandibles. Materials and Methods: Artificial intracapsular fractures were created with a steel disk and electronic micromotor. The first group was fixed with 15 mm long self-tapping 2.0 mm system titanium screws and the second group was fixed with 15 mm long 2.4 mm bioresorbable screws. Linear loads of 25, 50, 75, 100 N was applied in anteroposterior direction to the hemimandibles and the data were transmitted directly from the load cell to a computer that shows emergent results of material characteristics under same forces as a graphic containing force and displacement. Results: The results show that there were no significant differences between the two methods, with 25 N of loading. (P > 0,05) The difference became significant with a higher value of loading. Conclusion: The results suggest that treatment with a single resorbable screw is not functionally stable as a single titanium screw.en_US
dc.language.isoengen_US
dc.publisherMedknow Publications & Media Pvt Ltden_US
dc.relation.isversionof10.4103/1119-3077.158946en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIntracapsular condylar fracturesen_US
dc.subjectosteosynthesisen_US
dc.subjectscrew fixationen_US
dc.titleBiomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental studyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume18en_US
dc.identifier.issue5en_US
dc.identifier.startpage589en_US
dc.identifier.endpage593en_US
dc.relation.journalNigerian Journal of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US