Basit öğe kaydını göster

dc.contributor.authorAcar, Ebru Turkoz
dc.contributor.authorOnar, Atiye Nur
dc.date.accessioned2020-06-21T13:40:34Z
dc.date.available2020-06-21T13:40:34Z
dc.date.issued2016
dc.identifier.issn1300-0527
dc.identifier.urihttps://doi.org/10.3906/kim-1504-81
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13832
dc.descriptionAcar, Ebru Turkoz/0000-0002-8164-6617en_US
dc.descriptionWOS: 000368558900001en_US
dc.description.abstractThe electrochemical behavior of valproic acid (VAL) was investigated using square wave voltammetry, cyclic voltammetry, and sampled direct current polarography and a new square wave voltammetric method was developed for determination of VAL in pharmaceutical preparations. VAL showed two reduction peaks at about -0.2 V and -0.8 V vs. Ag/AgCl 3 M KCl with a hanging mercury drop electrode in 0.05 M pH 3.3 Britton-Robinson (BR) buffer. These peaks were named peak I and peak II, respectively. The types of limiting current of both peaks were determined as diffusion controlled based on cyclic voltammetry studies. A linear calibration graph was obtained in the range 1.46 x 10(-4)-1.0 x 10(-3) M. The limit of detection (LOD) and limit of quantification (LOQ) were 1.09 x 10(-4) M (21.05 mu g/mL) and 1.10 x 10(-4) M (144.20 mu g/mL), respectively. Recovery studies for the accuracy of the method were performed by adding known amounts of VAL and it was found to be 109.67 +/- 4.85%. The proposed method was successfully applied to pharmaceutical products on the market.en_US
dc.description.sponsorshipOndokuz Mayis University, ResearchOndokuz Mayis University [F-209]en_US
dc.description.sponsorshipThis work was financially supported by Ondokuz Mayis University, Research Project No: F-209.en_US
dc.language.isoengen_US
dc.publisherScientific Technical Research Council Turkey-Tubitaken_US
dc.relation.isversionof10.3906/kim-1504-81en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSquare wave voltammetryen_US
dc.subjectdrug determinationen_US
dc.subjectvalproic aciden_US
dc.subjectvalproate analysisen_US
dc.subjectcarboxylic acid electrochemical-reductionen_US
dc.titleSquare wave voltammetric determination of valproic acid in pharmaceutical Preparationsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume40en_US
dc.identifier.issue1en_US
dc.identifier.startpage106en_US
dc.identifier.endpage116en_US
dc.relation.journalTurkish Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster