Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers

Tarih

2016

Yazar

Can, Ertugrul
Duran, Mustafa
Cetinkaya, Tugba
Ariturk, Nursen

Üst veri

Tüm öğe kaydını göster

Özet

AIMS: To evaluate a new noncontact optical biometer using partial-coherence interferometry and to compare the clinical measurements with those obtained from the device using optical low-coherence reflectometry (OLCR). SETTING AND DESIGN: Ondokuz Mayis University, Samsun, Turkey. Nonrandomized, prospective clinical trial SUBJECTS AND METHODS: The study was performed on the healthy phakic eyes of volunteers in the year 2014. Measurements of axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), mean keratometry (K), and white-to-white (WTW) measurements obtained with the low-time coherence interferometry (LTCI) were compared with those obtained with the OLCR. STATISTICAL ANALYSIS USED: The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson's coefficient. RESULTS: We examined seventy participants with a mean age of 33.06 (+/- 9.7) (range: 19-53) years. AL measurements with LTCI and OLCR were 23.7 (+/- 1.08) mm and 23.7 (+/- 1.1) mm, respectively. ACD was 3.6 (+/- 0.4) mm and 3.5 (+/- 0.4) mm for LTCI and OLCR, respectively. The mean CCT measurements for both devices were 533 (+/- 28) mm and 522 (+/- 28) mm, respectively. The mean K readings measurements for LTCI and OLCR were 43.3 (+/- 1.5) D and 43.3 (+/- 1.5) D, respectively. The mean WTW distance measurements for both devices were 12.0 (+/- 0.5) mm and 12.1 (+/- 0.5) mm, respectively. CONCLUSIONS: Measurements with LTCI correlated well with those with the OLCR. These two devices showed good agreement for the measurement of all parameters.

Kaynak

Middle East African Journal of Ophthalmology

Cilt

23

Sayı

4

Bağlantı

https://doi.org/10.4103/0974-9233.194075
https://hdl.handle.net/20.500.12712/13062

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.