Basit öğe kaydını göster

dc.contributor.authorTopcu, Cihan
dc.contributor.authorColdur, Fatih
dc.contributor.authorAndac, Muberra
dc.contributor.authorCubuk, Osman
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorCaglar, Bulent
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2020-06-21T13:31:56Z
dc.date.available2020-06-21T13:31:56Z
dc.date.issued2016
dc.identifier.issn0253-5106
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13060
dc.descriptionWOS: 000390364000010en_US
dc.description.abstractA polyvinylchloride (PVC) membrane silver(I) selective electrode was developed for the determination of silver(I) ions in photographic film developing solutions. The electrode was embedded into a home-made flow cell and successfully used as a potentiometric detector in a flow injection potentiometric (FIP) system. Under the optimized flow injection conditions, the electrode exhibited a non-Nernstian slope of 67.20 +/- 0.80 mV in the linear range from 1.0x10(-5) to 1.0x10(-1) mol/L (R-2 = 0.9961) and the lowest value for limit of detection (LOD) was calculated as 7.1x10(-6) mol/L. The electrode displayed good sensitivity, selectivity, repeatable and rapid response towards silver(I) ions. Lifetime of the electrode was determined as at least two months in FIP system. The electrode was also successfully applied for the potentiometric determination of silver(I) ions in photographic film developing solution samples in FIP system. The results attained from FIP system were compared with the atomic absorption spectrophotometry (AAS) results by using student's t-test at 95 % confidence level and relative deviation (RD) between the two methods was < 8 %.en_US
dc.language.isoengen_US
dc.publisherChem Soc Pakistanen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSilver(I) selective electrodeen_US
dc.subjectFlow injection potentiometryen_US
dc.subjectPhotographic film developing solutionen_US
dc.subjectPotentiometric analysisen_US
dc.titleFlow Injection Potentiometric Determination of Silver(I) in Photographic Film Developing Solution Samples by Polyvinylchloride Membrane Silver(I) Selective Electrodeen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume38en_US
dc.identifier.issue5en_US
dc.identifier.startpage882en_US
dc.identifier.endpage888en_US
dc.relation.journalJournal of the Chemical Society of Pakistanen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster