dc.description.abstract | Timely diagnosis of ischaemia-reperfusion (IR)-induced injury after testicular torsion may be critical for saving reproductive function. The purpose of this study was to detect IR-induced injury, indicated by E-selectin overexpression, in murine testis using ultrasound molecular contrast imaging. Mice underwent 720(degrees) unilateral testicular torsion (ischaemia) followed by detorsion (reperfusion), and the control group (Sham-IR) was operated identically without extended ischaemia. In a separate positive control group, TNF- was injected intratesticularly to induce inflammation and compared to intratesticular saline injection. Selectin-targeted or nontargeted ultrasound contrast microbubbles were injected intravenously, and two-dimensional (2D) real-time high-resolution ultrasound testicular imaging was performed after reperfusion or after TNF- injection. Contrast intensity levels were significantly higher in the testis of the IR group as compared to the Sham-IR group after injection of targeted contrast microbubbles. Contrast intensities were similar between the IR and Sham-IR groups after injection of nontargeted microbubbles. In addition, targeted contrast intensity levels were significantly higher in the TNF--treated group as compared to the control group. This study indicates that ultrasound contrast molecular imaging with microbubbles targeted to E-selectin can be used to assess IR-induced testicular injury. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Wiley-Blackwell | en_US |
dc.relation.isversionof | 10.1111/and.12531 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | E-selectin | en_US |
dc.subject | microbubbles | en_US |
dc.subject | testis | en_US |
dc.subject | torsion | en_US |
dc.subject | ultrasound | en_US |
dc.title | Assessment of ischaemia-reperfusion injury in the mice testis by using contrast ultrasound molecular imaging | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 48 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.startpage | 907 | en_US |
dc.identifier.endpage | 913 | en_US |
dc.relation.journal | Andrologia | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |