dc.contributor.author | Simsek, Neslihan | |
dc.contributor.author | Keles, Ali | |
dc.contributor.author | Ahmetoglu, Fuat | |
dc.contributor.author | Akinci, Levent | |
dc.contributor.author | Er, Kursat | |
dc.date.accessioned | 2020-06-21T13:18:17Z | |
dc.date.available | 2020-06-21T13:18:17Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 2548-0839 | |
dc.identifier.uri | https://doi.org/10.5152/eej.2017.17004 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/12240 | |
dc.description | Er, Kursat/0000-0002-0667-4909 | en_US |
dc.description | WOS: 000414442600001 | en_US |
dc.description.abstract | Objective: This study used microcomputed tomography (micro-CT) to compare the volumes of voids and gaps in curved root canals instrumented and filled using various techniques. Methods: Twenty extracted mandibular first molars with two curved mesial root canals were used. Root canals were instrumented using a self-adjusting file (SAF) or Revo-S file system. For standardization, mesiobuccal canals were instrumented with SAF and mesiolingual canals were instrumented with Revo-S in each root. The canals were divided into four experimental groups (n=10 in each). The canals were then filled via cold lateral compaction (CLC) or a thermoplasticized injectable technique (TT) using gutta-percha and AH Plus root canal sealer. The roots were scanned with a micro-CT, and the volumes of the voids and gaps were calculated using three-dimensional (3D) micro-CT images. Data were analyzed using unpaired t- and Kruskal-Wallis tests. A value of P < 0.05 was considered significant. Results: None of the tested techniques provided void-or gap-free fillings. Nevertheless, the SAF showed more gap formation than the Revo-S, and TT showed higher gap formation in all experimental groups. These differences, however, were not statistically significant (p>0.05). Conclusion: The SAF and Revo-S rotary file systems yielded comparable results. No statistically significant difference was found between the results of the various instrumentation and filling techniques. | en_US |
dc.description.sponsorship | Inonu University, Malatya, Turkey, Scientific Research Projects UnitInonu University [201178] | en_US |
dc.description.sponsorship | This project was supported by Inonu University, Malatya, Turkey, Scientific Research Projects Unit (201178). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Aves Press Ltd | en_US |
dc.relation.isversionof | 10.5152/eej.2017.17004 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Micro-CT | en_US |
dc.subject | quality of obturation | en_US |
dc.subject | Revo-S | en_US |
dc.subject | Self-adjusting file | en_US |
dc.subject | void | en_US |
dc.subject | and gap | en_US |
dc.title | 3D Micro-CT Analysis of Void and Gap Formation in Curved Root Canals | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 2 | en_US |
dc.relation.journal | European Endodontic Journal | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |