• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Clinical effectiveness of 2 orthodontic retainer wires on mandibular arch retention

Tarih

2018

Yazar

Gunay, Firdevs
Oz, Abdullah Alper

Üst veri

Tüm öğe kaydını göster

Özet

Introduction: The aim of this study was to evaluate and compare the clinical success of 2 lingual retainer wires. Methods: The 120 patients included in the study were divided into 2 groups randomly. In group 1, 0.0175-in 6-strand stainless steel wire (Ortho Technology, Lutz, Fla) was used, the lingual retainers were fabricated on plaster models, and a silicon transfer key was used. In group 2, 0.0195-in dead-soft coaxial wire (Respond; Ormco, Orange, Calif) was used, and the lingual retainers were fabricated directly in the patient's mandibular arch without a study model. Pretreatment, posttreatment, and posttreatment 3-month, 6-month, 9-month, and 12-month 3-dimensional orthodontic models were evaluated. Failure rates, mandibular arch irregularity values, intercanine distances, and arch lengths were compared. Results: The clinical bond failure rates were 13.2% for the 0.0175-in 6-strand stainless steel wire and 18.9% for the 0.0195-in dead-soft wire. The difference in bond failures between the 2 groups was not statistically significant. There was a statistically significant increase in mandibular arch irregularity in both groups during the 12-month follow-up. However, the increase was significantly higher in the second group than in the first one. Furthermore, the intercanine distance decreased over time in the second group. Conclusions: Our findings regarding mandibular arch measurements indicate that fabrication of lingual retainers can be more safely accomplished with 0.0175-in 6-strand stainless steel wire than with 0.0195-in dead-soft coaxial wire.

Kaynak

American Journal of Orthodontics and Dentofacial Orthopedics

Cilt

153

Sayı

2

Bağlantı

https://doi.org/10.1016/j.ajodo.2017.06.019
https://hdl.handle.net/20.500.12712/11762

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.