Basit öğe kaydını göster

dc.contributor.authorPasali, Baris
dc.contributor.authorSarac, Duygu
dc.contributor.authorKaleli, Necati
dc.contributor.authorSarac, Yakup Sinasi
dc.date.accessioned2020-06-21T13:11:45Z
dc.date.available2020-06-21T13:11:45Z
dc.date.issued2018
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.urihttps://hdl.handle.net/20.500.12712/11759
dc.descriptionWOS: 000426145300012en_US
dc.descriptionPubMed: 28545869en_US
dc.description.abstractStatement of problem. Recently, presintered metal blocks for nonprecious and precious metal implant-supported restorations have gained popularity in computer-aided design and computer aided manufacturing (CAD-CAM) systems. However, few studies have evaluated the marginal discrepancy of implant-supported restorations made with these new alloy systems. Purpose. The purpose of this in vitro study was to compare the milling-sintering method with the lost-wax and milling methods in terms of the marginal fit of implant-supported metal-ceramic restorations. Material and methods. Thirty implant abutments screwed to implant analogs were embedded into acrylic resin to investigate marginal fit and then divided according to fabrication methods into the following 3 groups (n=10): lost-wax (LW; control group), milling (M), and milling-sintering (MS). Porcelain material was applied to all specimens after completion of the fabrication process. Subsequently, all specimens were cemented to implant abutments for the measurement of marginal discrepancies. Twelve marginal discrepancy measurements were recorded on each implant abutment by using a stereomicroscope. The arithmetic mean of these 12 measurements was considered the mean marginal discrepancy value of each abutment. Data were statistically analyzed by using 1-way ANOVA and Tukey honest significant difference tests (alpha=.05). Results. The lowest mean marginal discrepancy values (81 +/- 2 mu m) were observed in the M group, which was significantly different (P<.001) from the other methods. The highest mean marginal discrepancy values (99 +/- 2 mu m) were observed in the MS group. Conclusions. The results revealed that restorations prepared by the milling-sintering method provided clinically acceptable results (<120 mu m); however, this new technique was not found to be as precise as the milling method in terms of marginal fit.en_US
dc.language.isoengen_US
dc.publisherMosby-Elsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEvaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocksen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume119en_US
dc.identifier.issue2en_US
dc.identifier.startpage257en_US
dc.identifier.endpage262en_US
dc.relation.journalJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster