Application of hybrid external fixation by the "joystick method" in bicondylar tibial plateau fractures: Technical note

Tarih

2018

Yazar

Kuyucu, Ersin
Kara, Adnan
Say, Ferhat
Erdil, Mehmet
Bulbul, Murat
Gulenc, Baris

Üst veri

Tüm öğe kaydını göster

Özet

BACKGROUND: This study aimed to present clinical outcomes in patients with tibial plateau fractures who were treated with hybrid external fixators and describe the details of our technique. Schanz screws were synchronously applied and used as a joystick for fracture reduction. METHODS: The study population included 72 patients with bicondylar tibial plateau fractures classified as type 41 -C2 according to the AO classification. Joint reduction was maintained using Schanz screws transmitted through tibial condyles as a joystick under fluoroscopy. The patients then underwent surgery with these Schanz screws and a hybrid external fixation system. RESULTS: The median age of the patients was 39 (21-67) years, and the median follow-up time was 21 (12-35) months. The mean knee flexion and extension were 105 degrees (80 degrees-125 degrees) and 0 degrees (-5 degrees-7 degrees), respectively. The mean varus laxity and valgus laxity were 4.30 degrees (2 degrees-7 degrees) and 3.10 degrees (2 degrees-5 degrees), respectively. Four patients had leg shortness of 0.4-1.1 cm. The external fixators were removed between 8 and 16 weeks (mean = 11 weeks) postoperatively. The KSS scores at the end of I year were "excellent" for 48 patients. "good" for 19 patients, and "inadequate" for 5 patients. CONCLUSION: With the synchronous application of the two Schanz screws of 6.5-mm thickness and the two-drill technique under fluoroscopic guidance, we obtained stable reductions over a short period. No patient experienced major complications, and this enabled early weight bearing and a return to daily living activities.

Kaynak

Ulusal Travma Ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery

Cilt

24

Sayı

3

Bağlantı

https://doi.org/10.5505/tjtes.2017.27848
https://hdl.handle.net/20.500.12712/11651

Koleksiyonlar

  • Makale Koleksiyonu [9]
  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [4706]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.