• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Estimating the Value of the Volume From Acceleration on the Diaphragm Movements During Breathing

Tarih

2018

Yazar

Sumbul, Harun
Yuzer, A. Hayrettin

Üst veri

Tüm öğe kaydını göster

Özet

Information related to the movements of the diaphragm is very important and it is used in the detection of some respiratory diseases, which are common in all over the world, such as chronic obstructive pulmonary disease (COPD), asthma, and bronchitis. This article describes a practical method for estimating the value of the volume using the acceleration information on the diaphragm movements. The main goal of this paper is to develop a data collection system that measures acceleration values and to estimate the acceleration-volume relationship by examining the obtained data. Thus, two important parameters (TVC and FVC) in the diagnosis of COPD are measured in a more practical way. In the present case, these two parameters can be measured in a hospital environment by an expensive medical device called "spirometry". For this purpose, our device is placed on the abdomen region of the patient, diaphragm movements are examined and values of the volume are estimated from acceleration data (total 416 accelerometric data). Measurements are performed simultaneously by the spirometry and the developed device. Pearson coefficient (p<0.01) is calculated to determine the correlation between the measured data by using devices. Results show us that there is a positive correlation between measured values of the two devices (accelerometric and spirometric). It can be concluded that there is an acceptable correlation (91.4%) between accelerometric and spirometric results and the estimate error margin is quite low (0.08). In this respect, this study is considered to be an alternative method to spirometry tests, which is used in diagnosing COPD.

Kaynak

Journal of Engineering Science and Technology

Cilt

13

Sayı

5

Bağlantı

https://hdl.handle.net/20.500.12712/11648

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.