Basit öğe kaydını göster

dc.contributor.authorOzbas, Engin
dc.date.accessioned2020-06-21T12:27:43Z
dc.date.available2020-06-21T12:27:43Z
dc.date.issued2019
dc.identifier.issn1302-0900
dc.identifier.issn2147-9429
dc.identifier.urihttps://doi.org/10.2339/politeknik.407258
dc.identifier.urihttps://hdl.handle.net/20.500.12712/10967
dc.descriptionWOS: 000456781300015en_US
dc.description.abstractAn experimental study is carried out to investigate the pressure distribution and thermal performance of gravity assisted heat pipe charged with different working fluids. Methanol, water and Mono-Ethylene-Glycol (MEG) are chosen as working fluids which have different boiling point, density and viscosity. An experimental test apparatus is designed and produced including three heat pipes that heat input on the evaporator section are provided by solar energy. Measurements are conducted on the heat pipe surface for pressure and temperature variations. Pure antifreeze is chosen as working fluid, due to its high boiling point, along with water and methanol which are widely used in thermosyphon type heat pipes. Heat pipes are put into parabolic focused vacuumed glass tube and operated by solar energy for 11 days in order to achieve high temperatures. Data taken from 06.30 to 18.30 is taken into consideration for experimental results. Experimental results are evaluated for two days as (i) sunny and (ii) cloudy days by choosing days with the highest and lowest solar radiation. (i) As for the sunny day, the highest storage water temperatures for methanol, water and antifreeze were 90.0 degrees C, 83.5 degrees C and 86.7 degrees C and the pressure values were 6.7 bar, 1.6 bar and 1.9 bar respectively. (ii) And for the cloudy day, the respective values of temperature and pressure were measured as; 43.9 degrees C, 39.3 degrees C, 29.0 degrees C, and 2.0 bar, 0.2 bar and -0.3 bar.en_US
dc.language.isoengen_US
dc.publisherGazi Univen_US
dc.relation.isversionof10.2339/politeknik.407258en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHeat pipeen_US
dc.subjectsolar energyen_US
dc.subjectheatingen_US
dc.subjectperformanceen_US
dc.titleExperimental Study of Thermal Performance and Pressure Differences of Different Working Fluids in Two-phase Closed Thermosyphons Using Solar Energyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume22en_US
dc.identifier.issue1en_US
dc.identifier.startpage121en_US
dc.identifier.endpage128en_US
dc.relation.journalJournal of Polytechnic-Politeknik Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US