Basit öğe kaydını göster

dc.contributor.authorErzurumlu, Zerrin Unal
dc.contributor.authorGuler, Cigdem
dc.contributor.authorCender, Ebru Uslu
dc.contributor.authorCakici, Elif B.
dc.contributor.authorCankaya, Soner
dc.date.accessioned2020-06-21T12:26:14Z
dc.date.available2020-06-21T12:26:14Z
dc.date.issued2019
dc.identifier.issn1059-910X
dc.identifier.issn1097-0029
dc.identifier.urihttps://doi.org/10.1002/jemt.23355
dc.identifier.urihttps://hdl.handle.net/20.500.12712/10695
dc.descriptionERZURUMLU, ZERRIN UNAL/0000-0002-8693-1206; Guler, Cigdem/0000-0002-2581-9050en_US
dc.descriptionWOS: 000479834400001en_US
dc.descriptionPubMed: 31368622en_US
dc.description.abstractThe aim of this article is to compare the effects of 1.5 T and 3 T MRI on microleakage of amalgam restorations. A total of 90 extracted molar teeth were used in this study. Amalgam was used to restore standard Class V preparations (5 x 3 x 2 mm). Following the restoration, the teeth were divided into three groups according to magnetic resonance imaging (MRI) protocol (Group I: Control, Group II: 1.5 T MRI, and Group III: 3 T MRI). A total of 6,000 thermal cycles at 5 degrees C-55 degrees C were applied on all samples. Microleakage values were measured in millimeters using the ImageJ program. Microleakage values were higher in the gingival region compared to the occlusal region in all groups and the differences were statistically significant (p < .05). Microleakage values were not statistically different among the groups in the occlusal region (p > .05), while there were statistically significant differences among the groups with respect to microleakage values in the gingival region (p < .01). The highest mean microleakage amount in the gingival region was measured in Group III (1.192 +/- 0.941 mm). This was followed by Group II (0.519 +/- 0.813 mm) and Group I (0.347 +/- 0.726 mm), respectively. Within the limitations of this in vitro study, we observed that higher microleakage values in amalgam restored teeth in which were exposed to MRI procedure. We also found that the teeth exposed to the stronger magnetic field showed higher microleakage amount.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1002/jemt.23355en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectdental amalgamen_US
dc.subjectmagnetic resonance imagingen_US
dc.subjectmicroleakageen_US
dc.titleThe effect of 1.5 T and 3 T magnetic resonance imaging on microleakage of amalgam restorationsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume82en_US
dc.identifier.issue11en_US
dc.identifier.startpage1878en_US
dc.identifier.endpage1883en_US
dc.relation.journalMicroscopy Research and Techniqueen_US