Peri-implant bone defects: A 1-year follow-up comparative study of use of hyaluronic acid and xenografts

Tarih

2019

Yazar

Kaya, O. A.
Muglali, M.
Torul, D.
Kaya, I.

Üst veri

Tüm öğe kaydını göster

Özet

Objective: The aim of this study was to compare the efficacy of hyaluronic acid (HA) and xenografts on the repair of peri-implant dehiscence-type bone defects occur during implant placement. Patients and Methods: Forty-two dehiscence Class I type defects located on the buccal surface of the implants were included in this study. Defects were divided into two main groups as small sized (height of <3 mm) and medium sized (height between 3 and 5 mm). Both of the main groups were further divided into two subgroups as HA plus xenograft plus collagen membrane (HAXC) or xenograft plus collagen membrane (XC) applied groups. After grafting, repair of defect site was evaluated with the help of the cross-sectional images on cone-beam computed tomography at 6(th) and 12(th) months. Results: In both main groups, vertical bone height (VBH) was higher in defects repaired with HAXC (2.65 +/- 1.12 mm) than in the XC (2.45 +/- 1.10 mm) groups at the 6(th) month. However, the difference between two subgroups was not statistically significant (P > 0.05). Reduction in VBH was observed up to 6-12 months after prosthetic loading in all defect sites. This reduction was found statistically significant in medium-sized defects that grafted with XC (P < 0.05, paired t-test). However, in other subgroups, the difference between measurements at 6(th) and 12(th) months was not statistically significant (P > 0.05). Conclusions: According to the data obtained from this study, it can be concluded that HA did not have a significant positive effect on the repair of defects around dental implants.

Kaynak

Nigerian Journal of Clinical Practice

Cilt

22

Sayı

10

Bağlantı

https://doi.org/10.4103/njcp.njcp_502_18
https://hdl.handle.net/20.500.12712/10557

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.