• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Noninvasive cardiac output measurement based optimization in nonresponders of cardiac resynchronization therapy

Tarih

2020

Yazar

Yenercag, Mustafa
Yuksel, Serkan
Coksevim, Metin
Akcay, Murat
Arslan, Ugur

Üst veri

Tüm öğe kaydını göster

Özet

Background Cardiac resynchronization therapy (CRT) is an important and effective therapy for end-stage heart failure (HF). Nonresponse to CRT is one of the main obstacles to its application in clinical practice. Herein, we investigated the utilization of the optimization technique using noninvasive cardiac output measurement (NICOM) based Mobil-O-Graph device that measures several circulation parameters noninvasively. Methods Seventy-five CRT nonresponder HF patients with an implanted CRT device were included. Patients were randomized equally to 3 groups: NICOM, echocardiographic, and empirical optimization groups. After 3 months of optimization, changes in six minutes walk test (6-MWT), cardiac output (CO), left ventricular ejection fraction (LVEF), and end-systolic volume (LVESV) were measured. New York Heart Association (NYHA) class and hospitalization for HF were also determined. Results There were no statistically significant differences among the three groups in terms of demographics, baseline characteristics. In the NICOM group, the 6-MWT, LVEF, CO, and LVESV measurements showed significant improvements compared to baseline values (P < .05). There was no significant improvement in 6-MWT, LVEF, CO, NYHA class, and LVESV in Echo and Empirical groups after 3 months (P > .05). 6-MWT, CO, LVESV percentages, and hospitalization for HF were significantly different between the groups (P < .05). In post hoc analyzes, the percentages of the change in 6-MWT, CO, LVESV, and hospitalization for HF were significantly higher in the NICOM group (P < .017). Conclusions This study suggests that Mobil-O-Graph device optimization according to CO measures does appear to have potential hemodynamic and clinical benefits in nonresponder CRT patients. Use of Mobil-O-Graph device as an option for optimization of CRT devices can be an attractive method of improving CRT outcomes.

Kaynak

Pace-Pacing and Clinical Electrophysiology

Cilt

43

Sayı

4

Bağlantı

https://doi.org/10.1111/pace.13904
https://hdl.handle.net/20.500.12712/10094

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.