Basit öğe kaydını göster

dc.contributor.authorYagmur, Caglayan
dc.contributor.authorEvin, Nuh
dc.contributor.authorKelahmetoglu, Osman
dc.contributor.authorKucuker, Ismail
dc.contributor.authorKodalak, Enes Agah
dc.contributor.authorDemir, Ahmet
dc.date.accessioned2020-06-21T12:17:56Z
dc.date.available2020-06-21T12:17:56Z
dc.date.issued9999
dc.identifier.issn0364-216X
dc.identifier.issn1432-5241
dc.identifier.urihttps://doi.org/10.1007/s00266-020-01756-5
dc.identifier.urihttps://hdl.handle.net/20.500.12712/10026
dc.descriptionWOS: 000534116800003en_US
dc.descriptionPubMed: 32424533en_US
dc.description.abstractIntroduction The nasal septum plays an important role in nasal form and function. In this study, we describe a novel, alternative septoplasty approach that results in an aesthetically acceptable dorsal profile and improves airway function in patients with a crooked nose. Patients and Methods This study enrolled 26 patients who presented with crooked noses between 2012 and 2017. All patients underwent open rhinoplasty under general anesthesia. During correction of the cartilaginous part, a dorsal strip from the deviated septum was prepared and inverted in a 180 degrees fashion to exert a counter-force to correct the remaining septum and fixed by suturation. This maneuver allowed application of the maximum possible force in the opposite direction to reset the deviation by its own force. Results The approach was used successfully in 26 patients with severe nasal septal deviations in the caudal septum and dorsal angulation of the nasal shape. There was no case of hematoma, synechia, septal perforation, dorsal irregularity, or saddle deformity. Temporary nasal obstruction occurred in 4 patients but improved in all of them by the third postoperative month. One patient had a recurrence of the septal deviation, dorsal angulation, and persistent nasal obstruction, which were treated by revision nasal valve surgery 14 months postoperatively. There was no subsequent recurrence during the long-term follow-up. The improvement between the preoperative and postoperative 12-month deviation angle measurements, Nasal Obstruction and Septoplasty Effectiveness (NOSE) scores were significant (P < 0.05), Improvement in the NOSE score correlated strongly and significantly with deviation angle changes and patient satisfaction. Conclusion Our counter-autografting technique in septoplasty is safe and effective in the correction of severe dorsal and/or caudal deviations, as long as the severely angulated cartilage septum remains in one piece after careful dissection.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s00266-020-01756-5en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCounter-autograften_US
dc.subjectCrooked noseen_US
dc.subjectNasal septumen_US
dc.titleCounter Autografting of Dorsal Septum in Crooked Noseen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.relation.journalAesthetic Plastic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster