Yazar "Ozyurek, T." için listeleme
-
Apical extrusion of debris using reciprocating files and rotary instrumentation systems
Uzun, I.; Guler, B.; Ozyurek, T.; Tunc, T. (Wolters Kluwer Medknow Publications, 2016)Background: To compare the preparation time and amount of apically extruded debris after the preparation of root canals in extracted human teeth using the reciprocating files and rotary nickel-titanium systems. Procedure: ... -
Buccal infiltration versus inferior alveolar nerve block in mandibular 2(nd) premolars with irreversible pulpitis
Yilmaz, K.; Tunga, U.; Ozyurek, T. (Medknow Publications & Media Pvt Ltd, 2018)Purpose: The purpose of this study is to compare the success rates of inferior alveolar nerve block (IANB) and buccal infiltration anesthesia of mandibular second premolar with irreversible pulpitis and to evaluate the ... -
Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files
Ozyurek, T.; Uslu, G.; Gundogar, M.; Yilmaz, K.; Grande, N. M.; Plotino, G. (Wiley, 2018)AimTo compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35 degrees C). MethodologyForty R-Pilot and 40 WOG Glider files were subjected ... -
Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature
Uslu, G.; Ozyurek, T.; Yilmaz, K.; Gundogar, M. (Wiley, 2018)AimTo examine the cyclic fatigue resistances of R-Pilot, HyFlex EDM and PathFile NiTi glide path files in S-shaped artificial canals. MethodologyTwenty R-Pilot (12.5/.04), 20 HyFlex EDM (10/.05) and 20 PathFile (19/.02) ... -
Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature
Yilmaz, K.; Uslu, G.; Gundogar, M.; Ozyurek, T.; Grande, N. M.; Plotino, G. (Wiley, 2018)AimTo compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. MethodologyTwenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 ... -
Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study
Yilmaz, K.; Uslu, G.; Ozyurek, T. (Springer Heidelberg, 2018)AimTo compare the effect of autoclave cycles on the surface topography and roughness of HyFlex CM and HyFlex EDM instruments using atomic force microscopy (AFM) analysis.MethodologyEight new files of each brand were ...