Yazar "Arici, Selim" için listeleme
-
The clinical and laboratory effects of bracket type during canine distalization with sliding mechanics
Oz, A. Alper; Arici, Nursel; Arici, Selim (E H Angle Education Research Foundation, Inc, 2012)Objective: To compare the extent of canine movement with sliding mechanics between a self-ligating (SC) bracket and a modified twin design (MT) bracket. To test the in vitro coefficient of friction (COFs) of these two metal ... -
Comparison of different toothbrushing protocols in poor-toothbrushing orthodontic patients
Arici, Selim; Alkan, Arzu; Arici, Nursel (Oxford Univ Press, 2007)The aim of this study was to determine, using a computerized image analysing system, whether the use of a curved-bristle toothbrush (CBT) alone is more effective than two other toothbrushing protocols on dental plaque ... -
Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique
Arici, Nurse; Akdeniz, Berat Serdar; Arici, Selim (Korean Assoc Orthodontists, 2015)Objective: The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer ... -
The Effect of Different Doses of Extracorporeal Shock Waves on Experimental Model Mandibular Distraction
Bereket, Cihan; Cakir-Ozkan, Nilufer; Onger, Mehmet Emin; Arici, Selim (Lippincott Williams & Wilkins, 2018)Objective: Distraction osteogenesis (DO) is widely used treatment for the bone deformities. In addition extracorporeal shock wave therapy (ESWT) is a new perspective on noninvasive modalities of management of the bone ... -
The Effect of Implant Therapy on Maximum Bite Force in Edentulous Elderly Patients: An in Vivo Study
Sener, Ismail; Aslan, M. Ali; Tek, Mustafa; Bereket, Cihan; Arici, Selim; Sato, Shuichi (Gunes Kitabevi Ltd Sti, 2015)Introduction: The purpose of the present study was to compare the bite force differences between conventional complete denture prostheses and implant retained overdentures. Materials and Method: The study group consisted ... -
The effect of periodontal surgery on bite force, occlusal contact area and bite pressure
Alkan, Arzu; Keskiner, Ilker; Arici, Selim; Sato, Shuichi (Amer Dental Assn, 2006)Background. Tooth mobility resulting from the loss of periodontal support or trauma induced. by periodontal surgery may change. the amount of bite force (BF) and bite pressure (BP) and number of occlusal contact areas ... -
The effect of periodontitis on biting abilities
Alkan, Arzu; Keskiner, Ilker; Arici, Selim; Sato, Shuichi (Amer Acad Periodontology, 2006)Background: The aim of this study was to compare the biting abilities (bite force [BF] and occlusal contact area [OCA]) of chronic periodontitis patients with those of control patients with healthy periodontia by using ... -
Effects of first molar extraction on third molar angulation and eruption space
Bayram, Mehmet; Oezer, Mete; Arici, Selim (Mosby-Elsevier, 2009)Objectives. The aim was to investigate the effects of orthodontic treatment with 4 first molar extractions on the angulations and eruption spaces of all third molars and to compare these changes with outcomes of nonextraction ... -
Effects of fixed functional appliance treatment on the temporomandibular joint
Arici, Selim; Akan, Huseyin; Yakubov, Kamran; Arici, Nursel (Mosby-Elsevier, 2008)Introduction: In this study, we tested the hypothesis that fixed functional appliance treatment in a group of Class II Division 1 patients with mandibular retrusion changes the condyle position in the glenoid fossa. Methods: ... -
In Vitro Biomechanical Evaluation of Modified Plating Techniques for Bilateral Sagittal Split Ramus Osteotomy in Mandibular Advancement
Sener, Ismail; Arici, Selim; Bereket, Cihan; Tek, Mustafa (Lippincott Williams & Wilkins, 2012)The aim of this study was to compare the biomechanical properties of modified plate techniques using a newly designed three-dimensional test model after sagittal split ramus osteotomy. Fifteen synthetic polyurethane ... -
In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times
Oz, Abdullah Alper; Oz, Aslihan Zeynep; Arici, Selim (Mosby-Elsevier, 2016)Introduction: The purpose of this study was to compare the clinical failure rates and the in-vitro bond strengths of metal brackets bonded with different light-emitting diode (LED) devices and curing times. Methods: Forty ... -
Investigation of the effect of titanium alloy surface coating with different techniques on titanium-porcelain bonding
Aslan, Muhammed Ali; Ural, Cagri; Arici, Selim (Mosby-Elsevier, 2016)Statement of Problem. The bond strength of dental porcelain to titanium is inadequate as a clinical alternative to conventional alloys for metal ceramic restorations. Purpose. The purpose of this in vitro study was to ... -
Nonextraction treatment with rapid maxillary expansion and mandibular symphyseal distraction osteogenesis and vertical skeletal dimensions
Bayram, Mehmet; Ozer, Mete; Arici, Selim; Alkan, Alper (E H Angle Education Research Foundation, Inc, 2007)Objective: To investigate the effects of rapid maxillary expansion (RME) and mandibular symphyseal distraction osteogenesis (MSDO) on vertical dimensions of the face. Materials and Methods: Fourteen patients, nine girls ... -
Postfabrication thickness of single- and double-layered pressure-formed mouthguards
Sen Tunc, Emine; Ozdemir, Turkan Egilmez; Arici, Selim (Wiley, 2013)AimThe thickness of a mouthguard (MG) plays an important role in its primary function of preventing injuries. Multi-layered MGs have recently come into prominent use due to the disadvantages associated with single-layered ... -
Using Hemostatic Agents During Orthodontic Bonding: An in Vitro Study
Akdeniz, Berat Serdar; Oz, Abdullah Alper; Arici, Nursel; Demir, Onur; Arici, Selim (Aves, 2015)Objective: The aim of this in vitro study was to compare the effect of a traditional hemostatic agent on the shear bond strength (SBS) of conventional and self-etching bonding systems to find an efficient procedure for ...