Publication:
Salen Bileşenlerinde Temel Teşkil Eden Bütünüyle Katı Hal Kontakt Pvc Membran İyon Seçici Elektrotlar

dc.contributor.advisorIşıldak, Prof.dr. İbrahim
dc.contributor.authorMutlu, Semanur
dc.date.accessioned2020-07-21T21:39:40Z
dc.date.available2020-07-21T21:39:40Z
dc.date.issued2005
dc.departmentOMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalıen_US
dc.departmentFen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı
dc.descriptionTez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2005en_US
dc.descriptionLibra Kayıt No: 20927en_US
dc.description.abstractİİ SALEN BİLEŞİKLERİNDE TEMEL TEŞKİL EDEN BÜTÜNÜYLE KATI HAL KONTAKT PVC MEMBRAN İYON SEÇİCİ ELEKTROTLAR ÖZET Bazı salen bileşikleri (N,N-etilen bis(salisiladenamin)) kullanılarak bütünüyle katı-hal kontakt PVC-membran iyon-seçici elektrotlar hazırlanarak durgun ve hareketli ortamlarda test edildi. Elektrotların potansiyometrik performans karakteristikleri bilgisayar kontrollü ölçüm sisteminde test edildi. Hazırlanan elektrotların tamamına yakını ana iyon çözeltisine karşı Süper Nernst davranışı gösterdiği (>20 mV/her 10 kat derişim değişimi), cevap zamanlarının kısa (<12s) ve kullanım ömürlerinin uzun olduğu belirlendi (en az 1-2 ay). İyonofor-I üe hazırlanan elektrotun l.lO^-l.lO^moLL'1, İyonofor-II ile hazırlanan elektrotun İ.KT'-I.IO'6 moLL'1, îyonofor-III ile hazırlanan elektrotun LlO^-5.10'4 moLL'1 konsantrasyon arahğmda ana iyon çözeltisine karşı doğrusal davranış sergilediği görüldü. İyonofor I, iyonofor II ve iyonofor III olarak adlandırılan salen türevleri ile hazırlanan elektrotlar Fe3+ iyonuna karşı oldukça yüksek seçicilik gösterdiği gözlendi. Elektrotların ana iyon yanında girişim yapan iyonlara karşı seçicilik katsayıları 'ayrı çözelti metodu' ile hesaplanarak bulundu. Anahtar Kelimeler : Îyon-Seçici Elektrot, Katı-Hal Elektrot, PVC-Membran Elektrot, Demir (III), Salen Bileşikleri
dc.description.abstractIll SALEN COMPOUNDS BASED ON ALL SOLDD-STATE CONTACT PVC- MEMBRANE ION-SELECTIVE ELECTRODES ABSTRACT All solid-state contact PVC-membrane ion-selective electrodes based on salen (N,N-ethylene)bis(salicylideneaminate)) compounds were prepared and tested under static and dynamic conditions. The potentiometric performances of the prepared electrodes were tested by using a computer-controlled potentiometric system. All electrodes almost exhibited Super Nernstian behaviour (>60 mV/per decade), short response times (<12s), long life times (at least 2 months). With the electrode prepared 2 O -ft by Ionophore-I, a linear response was observed toward Fe + ion between 1.10' -1.10 mol.L'1 concentrations. A linear response between l.lO^-l.lO'6 mol.L'1 for ionophore II and between LlO^-S.lO^moLL'1 for ionophore-III were also observed for Fe3+ ion. Selectivity coefficients of the electrodes calculated by 'separate solution method' indicated that electrodes prepared with all active salen compounds exhibit very high selectivity toward Fe3+ ion. Keywords : Ion-Selective Electrode, Solid-State Electrode, PVC-Membrane Electrode, Iron (III), Salen Compoundsen_US
dc.formatX, 64 y. : şekil, tablo. ; 30 sm.en_US
dc.identifier.endpage74
dc.identifier.urihttp://libra.omu.edu.tr/tezler/20927.pdf
dc.identifier.yoktezid166134
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectChemistryen_US
dc.subjectKimya
dc.subject.otherTEZ YÜK LİS M992s 2005en_US
dc.titleSalen Bileşenlerinde Temel Teşkil Eden Bütünüyle Katı Hal Kontakt Pvc Membran İyon Seçici Elektrotlar
dc.titleSalen Compounds Based on All Solid-State PVC-Membrane Ion Selective Electrodesen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files