Publication: Contribution of a Locking Cross-Stitch to a Modified Kessler Core Suture: A New Technique
| dc.authorscopusid | 56025760100 | |
| dc.authorscopusid | 23484940100 | |
| dc.authorscopusid | 59748991100 | |
| dc.contributor.author | Gun̈eren, E. | |
| dc.contributor.author | Engin, M.S. | |
| dc.contributor.author | Özer, M. | |
| dc.date.accessioned | 2020-06-21T15:19:00Z | |
| dc.date.available | 2020-06-21T15:19:00Z | |
| dc.date.issued | 2007 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Gun̈eren] Ethem, Department of Plastic, Reconstructive, Spain, Üyesi Týp Fakültesi, Kurupelit, Samsun, Turkey; [Engin] M. S., Department of Plastic, Reconstructive, Spain; [Özer] Mete, Department of Orthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | We compared the gap-producing forces, ultimate tensile strength, and slip resistance of a new core suture technique and that of a modified Kessler suture in freshly harvested chicken tendons. Biomechanical trials were carried out using a tensile-strength testing machine. Our technique proved superior to the modified Kessler suture with respect to its ultimate tensile strength and slip resistance. © 2007 Lippincott Williams & Wilkins, Inc. | en_US |
| dc.identifier.doi | 10.1097/SAP.0b013e31802e8ae0 | |
| dc.identifier.endpage | 299 | en_US |
| dc.identifier.issn | 0148-7043 | |
| dc.identifier.issn | 1536-3708 | |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.pmid | 17721218 | |
| dc.identifier.scopus | 2-s2.0-34548258416 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 297 | en_US |
| dc.identifier.uri | https://doi.org/10.1097/SAP.0b013e31802e8ae0 | |
| dc.identifier.volume | 59 | en_US |
| dc.identifier.wos | WOS:000248989100012 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Lippincott Williams & Wilkins | en_US |
| dc.relation.ispartof | Annals of Plastic Surgery | en_US |
| dc.relation.journal | Annals of Plastic Surgery | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Biomechanical Study | en_US |
| dc.subject | Core Suture | en_US |
| dc.subject | Gap-Producing Force | en_US |
| dc.subject | Kessler Suture | en_US |
| dc.subject | Tendon Repair | en_US |
| dc.subject | Tensile Strength | en_US |
| dc.title | Contribution of a Locking Cross-Stitch to a Modified Kessler Core Suture: A New Technique | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |