Publication: Trace Analysis of Amines in Cheese Serum with Liquid Chromatographic Potentiometric Detection by Using Amine-Selective Electrode
| dc.authorscopusid | 57197614601 | |
| dc.authorscopusid | 55984370700 | |
| dc.authorscopusid | 55755380000 | |
| dc.authorscopusid | 6603596907 | |
| dc.contributor.author | Aydin, R. | |
| dc.contributor.author | Asan, A. | |
| dc.contributor.author | Attar, A. | |
| dc.contributor.author | Işıldak, I. | |
| dc.date.accessioned | 2020-06-21T12:19:35Z | |
| dc.date.available | 2020-06-21T12:19:35Z | |
| dc.date.issued | 2019 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Aydin] Rukiye, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Asan] Adem, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Attar] Azade, Department of Bioengineering, Yıldız Teknik Üniversitesi, Istanbul, Turkey; [Işıldak] İbrahim, Department of Bioengineering, Yıldız Teknik Üniversitesi, Istanbul, Turkey | en_US |
| dc.description.abstract | A trace quantification liquid chromatographic-potentiometric method for the determination of amines in cheese serum is described. An all solid-state contact polyvinyl chloride membrane amine-selective electrode was prepared and used as a detector in a low-dead volume flow through detection cell. Potentiometric performance characteristics of the proposed electrodes were then examined. A slope of 52.4±3.8 mV per decade toward amines was received at the concentration range of 1.0 × 10−2–8.0 × 10−6 M (r2 = 0.99) under dynamic conditions. Six amine compounds were separated, with a good resolution in the chromatographic system by using acetonitrile-methane sulfonic acid mobile phase gradient at the flow-rate of 1 mL min−1 in 30 min. The potentiometric detector was successfully applied to the analysis of amines in cheese serum samples. The relative standard deviations were ranged from 2.2% to 4.0% and recoveries were ranged from 88% to 101% for the determination. The average concentrations of ethylamine, butylamine and hexylamine in cheese serum samples calculated were 6.46, 4.51 and 8.37 μg L−1 respectively. © 2016 The Authors | en_US |
| dc.identifier.doi | 10.1016/j.arabjc.2016.07.006 | |
| dc.identifier.endpage | 4540 | en_US |
| dc.identifier.issn | 1878-5352 | |
| dc.identifier.issue | 8 | en_US |
| dc.identifier.scopus | 2-s2.0-84995460752 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 4533 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.arabjc.2016.07.006 | |
| dc.identifier.volume | 12 | en_US |
| dc.identifier.wos | WOS:000504900300263 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier B.V. | en_US |
| dc.relation.ispartof | Arabian Journal of Chemistry | en_US |
| dc.relation.journal | Arabian Journal of Chemistry | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Amine Analysis | en_US |
| dc.subject | Amine-Selective Electrodes | en_US |
| dc.subject | High Performance Liquid Chromatography | en_US |
| dc.subject | Potentiometric Detection | en_US |
| dc.title | Trace Analysis of Amines in Cheese Serum with Liquid Chromatographic Potentiometric Detection by Using Amine-Selective Electrode | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
