dc.description.abstractAim: Maintaining euvolemia is an important purpose in patients on hemodialysis therapy. Multiple-frequency bioimpedancespectroscopy (BIS) appears to be a useful and appropriate technique for assessing hydration status and body composition inhemodialysis patients.The aims of this study were to determine the pre and post hemodialysis hydration status of the pediatric hemodialysis patients by BIS and compare the dry weight determined by BIS to established by clinically.Material and Methods: Body Composition Monitor (BCM; Fresenius Medical Care, Germany) was performed in 13 pediatrichemodialysis patients in a single center. Patients were measured at the midweek session, once immediately before and once 30minutes after dialysis. Pre-and post-HD weights, blood pressures, were collected on the day of the BCM measurements.Results: Seven (53.8%) of the 13 patients were male and 6 (46.2%) were female. The mean age ranged from 11.92 ± 3.13 (5.7-16)years and duration time ranged from 7 to 54 months, and the median duration of dialysis was 11 months. Dry weights which wasdetermined clinically were higher than those calculated by BCM. A significant difference was found between mean values (34,71 ±12,68 versus 33,71 ± 12,16 kg, Δ: 1 ± 1,51, p = 0.035). There was a high positive correlation between dry weights measured by BCMand dry weight established by nephrologists (r = 0.993, p <0.001).Conclusion: In assessing dry weight, BCM appears to be a quick and easy-to-use tool that can assist the clinician in hemodialysistreatment and optimizing patient outcomesen_US
dc.identifier.doi10.5455/jtomc.2018.01.08
dc.identifier.endpage188en_US
dc.identifier.issn2636-7688
dc.identifier.issue2en_US
dc.identifier.startpage184en_US
dc.identifier.trdizinid285498
dc.identifier.urihttps://doi.org/10.5455/jtomc.2018.01.08
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/285498/assessment-of-bioelectrical-impedance-analysis-for-determining-dry-weight-in-pediatric-hemodialysis-patients-single-center-experience
dc.identifier.urihttps://hdl.handle.net/20.500.12712/45421
dc.identifier.volume25en_US
dc.language.isoenen_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGenel ve Dahili Tıpen_US
dc.titleAssessment of Bioelectrical Impedance Analysis for Determining Dry Weight in Pediatric Hemodialysis Patients; Single Center Experienceen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files