Publication: Relationship Between Dose and Stopping Power Values for Electrons in Skin and Muscle Tissues
| dc.authorscopusid | 57202847340 | |
| dc.authorscopusid | 8211625000 | |
| dc.authorwosid | Tufan, Mustafa/Abi-4079-2020 | |
| dc.authorwosid | Yuksel, Zeynep/Aai-9285-2021 | |
| dc.contributor.author | Yuksel, Zeynep | |
| dc.contributor.author | Tufan, M. Cagatay | |
| dc.contributor.authorID | Yüksel, Zeynep/0000-0001-7880-156X | |
| dc.date.accessioned | 2025-12-11T01:12:41Z | |
| dc.date.issued | 2021 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Yuksel, Zeynep] Ondokuz Mayis Univ, Vocat Sch Hlth Serv, Med Serv & Tech Dept, TR-55139 Samsun, Turkey; [Tufan, M. Cagatay] Ondokuz Mayis Univ, Grad Sch, Dept Radiol Sci, TR-55139 Samsun, Turkey | en_US |
| dc.description | Yüksel, Zeynep/0000-0001-7880-156X; | en_US |
| dc.description.abstract | Absorbed dose and stopping power of the target material are two important parameters for determining the radiation effects. In this work, the relationship between these two parameters has been investigated for electron beams incident on skin and muscle tissue. Absorbed dose was obtained by using the EGSnrc code and the stopping power values were calculated by considering the velocity-depended effective charge and mean excitation values. To obtain the relationship between absorbed dose and stopping power values, these parameters were graphed together and simple fitting functions have been obtained. The results obtained show that these parameters are linearly correlated with each other. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.1007/s00411-020-00888-1 | |
| dc.identifier.endpage | 140 | en_US |
| dc.identifier.issn | 0301-634X | |
| dc.identifier.issn | 1432-2099 | |
| dc.identifier.issue | 1 | en_US |
| dc.identifier.pmid | 33528674 | |
| dc.identifier.scopus | 2-s2.0-85100293159 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 135 | en_US |
| dc.identifier.uri | https://doi.org/10.1007/s00411-020-00888-1 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/42045 | |
| dc.identifier.volume | 60 | en_US |
| dc.identifier.wos | WOS:000613956400001 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Springer | en_US |
| dc.relation.ispartof | Radiation and Environmental Biophysics | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Absorbed Dose | en_US |
| dc.subject | Stopping Power | en_US |
| dc.subject | Electron | en_US |
| dc.subject | CSDA Range | en_US |
| dc.subject | EGSnrc | en_US |
| dc.title | Relationship Between Dose and Stopping Power Values for Electrons in Skin and Muscle Tissues | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
